Oxygen enriched treatment gases and Oxygen may be used. Air may be used if nothing better is available. If oxygen breathing is interrupted no compensation to the times is required. Oxygen partial pressure may not exceed 3 ata (3 bar). Maximum depth 165 fsw (50 msw) Time at 165 fsw optional from 30 minutes to 2 hours including compression
Z88.2 notes that these SCBAs normally use compressed air, but can also use cryogenic air or compressed oxygen. However, the standard warns that "the actual service time is usually less than the NIOSH rated service time". If compressed air is used, Z88.2 requires the use of "CGA G7.1–2011 Grade D breathing air". [14]
Medical oxygen storage tanks at the Royal Women's Hospital, Melbourne, Australia. Oxygen may be used for patients requiring supplemental oxygen via mask. Usually accomplished by a large storage system of liquid oxygen at the hospital which is evaporated into a concentrated oxygen supply, pressures are usually around 345–380 kPa (50.0–55.1 psi), [1] [2] or in the UK and Europe, 4–5 bar ...
The cylinders used were dural light-alloy cylinders holding 800 litres or RAF steel wire-wound cylinders holding 1,400 litres of oxygen (both at 3,300 p.s.i.; 227.5 bar or 22.75 MPa). The expedition had 8 closed-circuit and 12 open-circuit sets; the open-circuit set used 1 RAF cylinder or 1, 2 or 3 dural cylinders; with total set weight 28 lb ...
Medical use liquid oxygen airgas tanks are typically 2.4 MPa (350 psi). [citation needed] All equipment coming into contact with high pressure oxygen must be "oxygen clean" and "oxygen compatible", to reduce the risk of fire. [3] [4] "Oxygen clean" means the removal of any substance that could act as a source of ignition. "Oxygen compatible ...
A sodium chlorate oxygen candle in the base of the unit generates oxygen on start-up as the canister has to reach a high internal temperature before it will start generating oxygen. The circulation of exhaled air containing carbon dioxide through the canister starts the chemical process, usually taking less than five minutes to reach a stable ...
An oxygen tank is especially dangerous because the gas is stored at a pressure of 21 MPa (3,000 psi; 210 atm)) when full. If the tank falls over and damages the valve, the tank can be jettisoned by the compressed oxygen escaping the cylinder at high speed. Tanks in this state are capable of breaking through a brick wall. [19]