When.com Web Search

  1. Ads

    related to: 4 pipe fan coil

Search results

  1. Results From The WOW.Com Content Network
  2. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    The supply pipe supplies either cold or hot water to the unit depending on the time of year. Four-pipe fan coil units have two supply pipes and two return pipes. This allows either hot or cold water to enter the unit at any given time. Since it is often necessary to heat and cool different areas of a building at the same time, due to ...

  3. Leaside Towers - Wikipedia

    en.wikipedia.org/wiki/Leaside_Towers

    All suites within the two towers include seasonal central air-conditioning, and heating provided through a 4-pipe fan coil unit. A mixture of water and glycol is chilled to approximately 4 Celsius through water cooled centrifugal chillers located in the basement's utility room of both towers. A mechanical pump circulates the liquid through chilled water risers extending the length

  4. Run-around coil - Wikipedia

    en.wikipedia.org/wiki/Run-around_coil

    A run-around coil installation, serving air handling units on the roof of an office building. A run-around coil is a type of energy recovery heat exchanger most often positioned within the supply and exhaust air streams of an air handling system, or in the exhaust gases of an industrial process, to recover the heat energy. Generally, it refers ...

  5. Air handler - Wikipedia

    en.wikipedia.org/wiki/Air_handler

    Small air handlers, for local use, are called terminal units, and may only include an air filter, coil, and blower; these simple terminal units are called blower coils or fan coil units. A larger air handler that conditions 100% outside air, and no recirculated air, is known as a makeup air unit (MAU) or fresh air handling unit (FAHU).

  6. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    The two-pipe reverse return configuration which is sometimes called 'the three-pipe system' is different from the two-pipe system in the way that water returns to the boiler. In a two-pipe system, once the water has left the first radiator, it returns to the boiler to be reheated, and so with the second and third etc.

  7. Left-hander A.J. Minter and Mets finalize $22 million, 2-year ...

    www.aol.com/left-hander-j-minter-mets-211424135.html

    Left-hander A.J. Minter and the New York Mets finalized a $22 million, two-year contract on Thursday. Minter can opt out after the 2025 World Series and become a free agent again. The 31-year-old ...