When.com Web Search

  1. Ad

    related to: 1 phase and 3 difference in excel formula

Search results

  1. Results From The WOW.Com Content Network
  2. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    The phase angle difference between voltage and current of each phase is not necessarily 0 and depends on the type of load impedance, Z y. Inductive and capacitive loads will cause current to either lag or lead the voltage. However, the relative phase angle between each pair of lines (1 to 2, 2 to 3, and 3 to 1) will still be −120°.

  3. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    For example, balanced two-phase power can be obtained from a three-phase network by using two specially constructed transformers, with taps at 50% and 86.6% of the primary voltage. This Scott T connection produces a true two-phase system with 90° time difference between the phases.

  4. Smith chart - Wikipedia

    en.wikipedia.org/wiki/Smith_chart

    The length of the line would then be scaled to P 1 assuming the Smith chart radius to be unity. For example, if the actual radius measured from the paper was 100 mm, the length OP 1 would be 63 mm. The following table gives some similar examples of points which are plotted on the Z Smith chart. For each, the reflection coefficient is given in ...

  5. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    The power factor in a single-phase circuit (or balanced three-phase circuit) can be measured with the wattmeter-ammeter-voltmeter method, where the power in watts is divided by the product of measured voltage and current. The power factor of a balanced polyphase circuit is the same as that of any phase. The power factor of an unbalanced ...

  6. Phase (waves) - Wikipedia

    en.wikipedia.org/wiki/Phase_(waves)

    The difference () = () between the phases of two periodic signals and is called the phase difference or phase shift of relative to . [1] At values of t {\displaystyle t} when the difference is zero, the two signals are said to be in phase; otherwise, they are out of phase with each other.

  7. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. Symmetrical components - Wikipedia

    en.wikipedia.org/wiki/Symmetrical_components

    The imbalance between phases arises because of the difference in magnitude and phase shift between the sets of vectors. Notice that the colors (red, blue, and yellow) of the separate sequence vectors correspond to three different phases (A, B, and C, for example). To arrive at the final plot, the sum of vectors of each phase is calculated.