Worcester's gas, oil and LPG ranges consist of regular boilers, combination boilers and system boilers; these are wall-hung, floor-standing or externally sited. Worcester's solar water heating range was released in 2005, with the ground source heat pump range being released in 2007 and the air source heat pump range being released in 2008. [10]
The boiler will also fire (regardless of thermostat state) when the boiler water temperature goes below a range around the low limit, ensuring that the boiler water temperature remains above a certain point. The low limit is intended for tankless domestic hot water; it ensures that boiler water is always warm enough to heat the domestic hot water.
Inside the cracks, the water evaporates and the amount of hydroxide keeps increasing progressively. The concentrated area with high stress works as anode and diluted area works as cathode. At anode, sodium hydroxide attacks the surrounding material and then dissolves the iron of the boiler as sodium ferrate forming rust. This causes ...
Since the final exhaust from a condensing boiler has a lower temperature than the exhaust from an atmospheric boiler 38 °C (100 °F) vs. 204 °C (400 °F) a mechanical fan is always required to expel it, with the additional benefit of allowing the use of low-temperature exhaust piping (typically PVC in domestic applications) without insulation ...
Although the definitions are somewhat flexible, it can be said that older steam generators were commonly termed boilers and worked at low to medium pressure (7–2,000 kPa or 1–290 psi) but, at pressures above this, it is more usual to speak of a steam generator. A boiler or steam generator is used wherever a source of steam is required.
Boiler water is treated to prevent scaling, corrosion, foaming, and priming. Chemicals are put into boiler water through the chemical feed tank to keep the water within chemical range. These chemicals are mostly oxygen scavengers and phosphates. The boiler water also has frequent blowdowns in order to keep the chloride content down.
erosion of a boiler's plates from the internal water space, particularly where there is a step inside the shell. This was a problem for early boilers made from lapped plates rather than butted plates, and gave rise to many boiler explosions. In later years it was a problem for the non-circular water drums of Yarrow boilers. Handhole
Vanderbilt boiler An American design, similar to the Lentz and large launch-type boilers. [36] Velox boiler: [61] vertical boiler: flued or fire-tube designs where the main shell is a cylinder on a vertical axis, rather than horizontal. Boilers of this external form may have a great variety of internal arrangements.