The left atrial volume is commonly measured by echocardiography or magnetic resonance tomography.It is calculated from biplane recordings with the equation: = where A4c and A2c denote LA areas in 4- and 2-chamber views respectively, and L corresponds to the shortest long-axis length measured in either views.
Modalities applied to measurement of ejection fraction is an emerging field of medical mathematics and subsequent computational applications. The first common measurement method is echocardiography, [7] [8] although cardiac magnetic resonance imaging (MRI), [8] [9] cardiac computed tomography, [8] [9] ventriculography and nuclear medicine (gated SPECT and radionuclide angiography) [8] [10 ...
S in V 1 or V 2 ≥30 mm; R in V 5 or V 6 ≥30 mm; 3 ST-T Abnormalities: ST-T vector opposite to QRS without digitalis; ST-T vector opposite to QRS with digitalis; 3 1 Negative terminal P mode in V 1 1 mm in depth and 0.04 sec in duration (indicates left atrial enlargement) 3 Left axis deviation (QRS of −30° or more) 2 QRS duration ≥0.09 ...
Published normal ranges for LVMi are 49–115 g/m 2 for men and 43–95 g/m 2 for women. [1] [4] left ventricular hypertrophy (LVH) is defined as an abnormal increase in LVM, an important independent risk factor for cardiovascular morbidity and mortality.
Mitral regurgitation, also known as mitral insufficiency or mitral incompetence, is the backward flow of blood from the left ventricle, through the mitral valve, and into the left atrium, when the left ventricle contracts, resulting in a systolic murmur radiating to the left armpit.
Apical 4 chamber. This view is obtained at the apex of the heart and looking toward the base of the heart (where the valves are). In this view, the mitral valve, tricuspid valve, and all four chambers are visible. This view shows the right ventricle from base to apex and is a useful view to estimate RV systolic function.
A monitor unit (MU) is a measure of machine output from a clinical accelerator for radiation therapy such as a linear accelerator or an orthovoltage unit. Monitor units are measured by monitor chambers, which are ionization chambers that measure the dose delivered by a beam and are built into the treatment head of radiotherapy linear accelerators.
The velocity curves are in general taken from the base of the mitral annulus at the insertion of the mitral leaflets, in the septal and lateral points of the four chamber view, and eventually the anterior and inferior points of the two-chamber views. For the right ventricle it is customary to use the lateral point of the tricuspid annulus only.