When.com Web Search

  1. Ads

    related to: motor rated 3 phase toggle switch 3 pole

Search results

  1. Results From The WOW.Com Content Network
  2. Dahlander pole changing motor - Wikipedia

    en.wikipedia.org/wiki/Dahlander_pole_changing_motor

    A Dahlander motor (also known as a pole changing motor, dual- or two speed-motor) is a type of multispeed three-phase induction motor, in which the speed of the motor is varied by altering the number of poles; this is achieved by altering the wiring connections inside the motor.

  3. Rotary phase converter - Wikipedia

    en.wikipedia.org/wiki/Rotary_phase_converter

    A three-phase induction motor can be run at two-thirds of its rated horsepower on single-phase power applied to a single winding, once spun up by some means. A three-phase motor running on a single phase cannot start itself because it lacks the other phases to create a rotation on its own, much like a crank that is at dead center.

  4. IEC 60034 - Wikipedia

    en.wikipedia.org/wiki/IEC_60034

    In the European Community the IE2 class is mandatory for all new motors since 16 June 2011. The IE3 class will be mandatory from 1 January 2015 (7.5–375 kW) and 1 January 2017 (0.75–375 kW). [2] From June 1, 2021, three-phase motors from 0.75 kW to 1000 kW must meet at least IE3 efficiency.

  5. Induction motor - Wikipedia

    en.wikipedia.org/wiki/Induction_motor

    For example; a single-phase motor with 3 north and 3 south poles, having 6 poles per phase, is a 6-pole motor. A three-phase motor with 18 north and 18 south poles, having 6 poles per phase, is also a 6-pole motor. This industry standard method of counting poles results in the same synchronous speed for a given frequency regardless of polarity.

  6. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    This allows one to choose single-phase AC power at either 110–120 volts between phase and neutral or 220–240 volts between phase and phase. Since these two modes do not need three phases there is also a dark yellow-orange four-pin connector available designed for a single-phase 110–120 or 220–240 volt load.

  7. Reluctance motor - Wikipedia

    en.wikipedia.org/wiki/Reluctance_motor

    When a rotor pole is equidistant from two adjacent stator poles, the rotor pole is said to be in the "fully unaligned position". This is the position of maximum magnetic reluctance for the rotor pole. In the "aligned position", two (or more) rotor poles are fully aligned with two (or more) stator poles, (which means the rotor poles completely ...