The recommended level of indoor humidity is in the range of 30–60% in air conditioned buildings, [34] [35] but new standards such as the adaptive model allow lower and higher humidity, depending on the other factors involved in thermal comfort. Recently, the effects of low relative humidity and high air velocity were tested on humans after ...
Much has been made about the dangerous pandemic pathogens flying around the air outside of our personal bubbles this year, but in the cold months ahead, the safety of indoor locations may be a ...
The World Health Organization in 1987 found that comfortable indoor temperatures of 18–24 °C (64–75 °F) were not associated with health risks for healthy adults with appropriate clothing, humidity, and other factors. For infants, elderly, and those with significant health problems, a minimum of 20 °C (68 °F) was recommended.
For humidity ratios above 0.012 kg H 2 O/kg dry air (0.012 lb H 2 O/lb dry air), or for metabolic rates up to 2.0 met, the analytical model must be used to determine thermal comfort sensation. Also based on the PMV model, this method uses tools such as the ASHRAE Thermal Comfort Tool or the online CBE Thermal Comfort Tool for ASHRAE 55 [ 2 ] to ...
Indoor relative humidities should be kept above 30% to reduce the likelihood of the occupant's nasal passages drying out, especially in winter. [38] [41] [42] Air conditioning reduces discomfort by reducing not just temperature but humidity as well. Heating cold outdoor air can decrease relative humidity levels indoors to below 30%. [43]
The US Occupational Safety and Health Administration recommends indoor air be maintained at 20–24.5 °C (68–76 °F) with a 20–60% relative humidity, [12] equivalent to a dew point of approximately 4.0 to 16.5 °C (39 to 62 °F) (by Simple Rule calculation below).
Mold growth can be inhibited by keeping surfaces at conditions that are further from condensation, with relative humidity levels below 75%. This usually translates to a relative humidity of indoor air below 60%, in agreement with the guidelines for thermal comfort that recommend a relative humidity between 40 and 60 %.
T07 Humidity Control, control of humidity receives 1 point by having mechanical system that can maintain relative humidity 30% to 60% at all times or submitting document that modeled relative humidity levels in space from 30% to 60% for at least 98% of all business hours or by meeting thermal comfort monitoring (T06) with relative humidity ...