When.com Web Search

  1. Ad

    related to: split phase electrical systems work

Search results

  1. Results From The WOW.Com Content Network
  2. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    A split-phase or single-phase three-wire system is a type of single-phase electric power distribution. It is the alternating current (AC) equivalent of the original Edison Machine Works three-wire direct-current system.

  3. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Most of the Americas use 60 Hz AC, the 120/240 volt split-phase system domestically and three phase for larger installations. North American transformers usually power homes at 240 volts, similar to Europe's 230 volts. It is the split-phase that allows use of 120 volts in the home. Japan's utility frequencies are 50 Hz and 60 Hz.

  4. Polyphase system - Wikipedia

    en.wikipedia.org/wiki/Polyphase_system

    One voltage cycle of a three-phase system. A polyphase system (the term coined by Silvanus Thompson) is a means of distributing alternating-current (AC) electrical power that utilizes more than one AC phase, which refers to the phase offset value (in degrees) between AC in multiple conducting wires; phases may also refer to the corresponding terminals and conductors, as in color codes.

  5. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Current practice is to give separate services for single-phase and three-phase loads, e.g., 120 V split-phase (lighting etc.) and 240 V to 600 V three-phase (for large motors). However, many jurisdictions forbid more than one class for a premises' service, and the choice may come down to 120/240 V split-phase, 208 V single-phase or three-phase ...

  6. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    In North America, single-family houses and individual apartments are supplied one phase from the power grid and use a split-phase system to the panelboard from which most branch circuits will carry 120 V. Circuits designed for higher powered devices such as stoves, dryers, or outlets for electric vehicles carry 240 V.

  7. Service drop - Wikipedia

    en.wikipedia.org/wiki/Service_drop

    From there they pass through the wall of the house to the electric panel and Main Fuses or Circuit Breakers inside. In North America, the 120/240 V split phase system is used for residential service drops. [3] [4] A pole-mounted single phase distribution transformer usually provides power for one or two residences. The secondary winding of the ...

  8. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    Neutral wires are usually connected at a neutral bus within panelboards or switchboards, and are "bonded" to earth ground at either the electrical service entrance, or at transformers within the system. For electrical installations with split-phase (three-wire single-phase) service, the neutral point of the system is at the center-tap on the ...

  9. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Because the phases are 120 degrees from each other, the voltage between any two phases is sqrt(3) * 230V = 400V, compared to the 2 * 120V = 240V in the North American split phase system. While three-phase power is almost unheard of in individual North American residences, it is common in Europe for heavy loads such as kitchen stoves, air ...