When.com Web Search

  1. Ads

    related to: chemical indicator for sterilization

Search results

  1. Results From The WOW.Com Content Network
  2. Autoclave tape - Wikipedia

    en.wikipedia.org/wiki/Autoclave_tape

    For steam sterilization to occur, the entire item must completely reach and maintain 121°C for 15–20 minutes with proper steam exposure to ensure sterilization. The color-changing indicator of tape is usually lead carbonate based, which decomposes to lead(II) oxide. To protect users from lead – and because this decomposition can occur at ...

  3. List of instruments used in microbiological sterilization and ...

    en.wikipedia.org/wiki/List_of_instruments_used...

    used for steam sterilization A pressure cooker: used as a portable autoclave Biological and chemical indicators: Used to ascertain if a certain process has been completed, e.g. spores used in an autoclave are killed if autoclaving is properly done Filters: •Candle filter:

  4. Autoclave - Wikipedia

    en.wikipedia.org/wiki/Autoclave

    This contains a full sheet of chemical indicator placed in the center of a stack of paper. It is designed specifically to prove that the process achieved full temperature and time required for a normal minimum cycle of 134 °C for 3.5–4 minutes. [20] To prove sterility, biological indicators are used.

  5. Sterilization (microbiology) - Wikipedia

    en.wikipedia.org/wiki/Sterilization_(microbiology)

    Ethylene oxide treatment is the most common chemical sterilization method, used for approximately 70% of total sterilizations, and for over 50% of all disposable medical devices. [ 26 ] [ 27 ] Ethylene oxide treatment is generally carried out between 30 and 60 °C (86 and 140 °F) with relative humidity above 30% and a gas concentration between ...

  6. Silver nitrate - Wikipedia

    en.wikipedia.org/wiki/Silver_nitrate

    Silver nitrate is an inorganic compound with chemical formula AgNO 3. It is a versatile precursor to many other silver compounds, such as those used in photography. It is far less sensitive to light than the halides. [citation needed] It was once called lunar caustic because silver was called luna by ancient alchemists who associated silver ...

  7. Bioindicator - Wikipedia

    en.wikipedia.org/wiki/Bioindicator

    A biological indicator is also the name given to a process for assessing the sterility of an environment through the use of resistant microorganism strains (e.g. Bacillus or Geobacillus). [5] Biological indicators can be described as the introduction of a highly resistant microorganisms to a given environment before sterilization , tests are ...