Search results

  1. Results From The WOW.Com Content Network
  2. Current transformer - Wikipedia

    en.wikipedia.org/wiki/Current_transformer

    Because the gaps in the hinged segment introduce inaccuracy, such devices are not normally used for revenue metering. Split-Core Current transformer. Current transformers, especially those intended for high voltage substation service, may have multiple taps on their secondary windings, providing several ratios in the same device.

  3. Instrument transformer - Wikipedia

    en.wikipedia.org/wiki/Instrument_transformer

    The primary winding of the transformer is connected to the high voltage or high current circuit, and the meter or relay is connected to the secondary circuit. Instrument transformers may also be used as an isolation transformer so that secondary quantities may be used in phase shifting without affecting other primary connected devices. [1]

  4. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    Current transformers used in metering equipment for three-phase 400 ampere electricity supply. A current transformer (CT) is a series connected measurement device designed to provide a current in its secondary coil proportional to the current flowing in its primary.

  5. Voltage transformer - Wikipedia

    en.wikipedia.org/wiki/Voltage_transformer

    A capacitor voltage transformer (CVT), is a transformer used in power systems to step down extra high voltage signals and provide a low voltage signal to the actual VT (voltage transformer) used for operating metering/protective relays due to a lower cost than an electromagnetic PT. The circuit diagram for a simple capacitor voltage transformer

  6. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    The transformer is always connected to the primary distribution lines through protective fuses and disconnect switches. For pole-mounted transformers, this is usually a 'fused cutout.' An electrical fault melts the fuse, and the device drops open to give a visual indication of trouble.

  7. Substation - Wikipedia

    en.wikipedia.org/wiki/Substation

    A circuit breaker is used as a protection device to interrupt fault currents automatically, and may be used to switch loads on and off, or to cut off a line when power is flowing in the 'wrong' direction. When a large fault current flows through the circuit breaker, this is detected through the use of current transformers. The magnitude of the ...

  8. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three independent single-phase units.

  9. Distribution Transformer Monitor - Wikipedia

    en.wikipedia.org/wiki/Distribution_Transformer...

    DTM device readings can “fill in the blanks” whenever an AMI meter in a group of meters on the same transformer fails to report properly for any reason. Assuming there is no diversion, the DTM can provide the utility with the substantially accurate missing consumption information, helping to assure the customer can be billed more accurately ...