Ad
related to: fluke multimeter probe set up manual
Search results
Results From The WOW.Com Content Network
Thus a meter with a 50 μA movement will have a "sensitivity" of 20,000 Ω/V. "Per volt" refers to the fact that the impedance the meter presents to the circuit under test will be 20,000 Ω multiplied by the full-scale voltage to which the meter is set. For example, if the meter is set to a range of 300 V full scale, the meter's impedance will ...
Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...
Together, the companies developed the scopemeter, an instrument combining features of an oscilloscope and a multimeter. Fluke purchased the testing and measurements division of Philips in 1993 for $41.8 million. [2] The Philips PM series of measurement instruments was rebranded as Fluke. Fluke was bought by the Danaher Corporation in 1998.
Consequently, a one-meter high-impedance direct (1×) coaxial probe may load the circuit with a capacitance of about 110 pF and a resistance of 1 megohm. Oscilloscope probes are characterised by their frequency limit, where the amplitude response has fallen by 3 dB, and/or by their rise time t r {\displaystyle t_{r}} .
An electrical meter with integral AC current clamp is known as a clamp meter, clamp-on ammeter, tong tester, or colloquially as an amp clamp. A clamp meter measures the vector sum of the currents flowing in all the conductors passing through the probe, which depends on the phase relationship of the currents. Only one conductor is normally ...
A multimeter with a built in clamp facility. Pushing the large button at the bottom opens the lower jaw of the clamp, allowing the clamp to be placed around a conductor (wire). Depending on sensor, some can measure both AC and DC current. RF probe; Signal tracer
Setting the probe scaling incorrectly is a common error, and throws the reading off by a factor of 10. Special high voltage probes form compensated attenuators with the oscilloscope input. These have a large probe body, and some require partly filling a canister surrounding the series resistor with volatile liquid fluorocarbon to displace air.
The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...