When.com Web Search

  1. Ads

    related to: fluke multimeter probe set up guide

Search results

  1. Results From The WOW.Com Content Network
  2. Multimeter - Wikipedia

    en.wikipedia.org/wiki/Multimeter

    Thus a meter with a 50 μA movement will have a "sensitivity" of 20,000 Ω/V. "Per volt" refers to the fact that the impedance the meter presents to the circuit under test will be 20,000 Ω multiplied by the full-scale voltage to which the meter is set. For example, if the meter is set to a range of 300 V full scale, the meter's impedance will ...

  3. Fluke Corporation - Wikipedia

    en.wikipedia.org/wiki/Fluke_Corporation

    Together, the companies developed the scopemeter, an instrument combining features of an oscilloscope and a multimeter. Fluke purchased the testing and measurements division of Philips in 1993 for $41.8 million. [2] The Philips PM series of measurement instruments was rebranded as Fluke. Fluke was bought by the Danaher Corporation in 1998.

  4. Test probe - Wikipedia

    en.wikipedia.org/wiki/Test_probe

    Flying leads are likely to pick up interference, so they are not suitable for low-level signals. Furthermore, the inductance of flying leads make them unsuitable for high frequency signals. Instead, a specific scope probe is used, which uses a coaxial cable to transmit the signal from the tip of the probe to the oscilloscope. This cable has two ...

  5. Four-terminal sensing - Wikipedia

    en.wikipedia.org/wiki/Four-terminal_sensing

    Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...

  6. Current clamp - Wikipedia

    en.wikipedia.org/wiki/Current_clamp

    An electrical meter with integral AC current clamp is known as a clamp meter, clamp-on ammeter, tong tester, or colloquially as an amp clamp. A clamp meter measures the vector sum of the currents flowing in all the conductors passing through the probe, which depends on the phase relationship of the currents. Only one conductor is normally ...

  7. Test light - Wikipedia

    en.wikipedia.org/wiki/Test_light

    Probes must be well-insulated, with minimal exposure of live terminals, with finger guards to prevent accidental contact, and must not expose live wires if the test lamp glass bulb is broken. To limit the energy delivered in case of a short circuit, test lights must have a current-limiting fuse or current-limiting resistor and fuse. The HSE ...

  8. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...

  9. Oscilloscope - Wikipedia

    en.wikipedia.org/wiki/Oscilloscope

    Setting the probe scaling incorrectly is a common error, and throws the reading off by a factor of 10. Special high voltage probes form compensated attenuators with the oscilloscope input. These have a large probe body, and some require partly filling a canister surrounding the series resistor with volatile liquid fluorocarbon to displace air.