The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.
The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...
Another feature of the Enwave system is that it is integrated with Toronto's drinking water supply. The Toronto drinking water supply required a new intake location that would be further from shore and deeper in the lake. This posed two problems for the utility that managed the city's drinking water supply: 1.
Chilled water; Chiller; Chiller boiler system; Chlorofluorocarbon; Chlorotrifluoroethylene; Climate shelters; Coefficient of performance; Cogeneration; Compost heater; Condenser (heat transfer) Constant air volume; Cooling; Cooling capacity; Cooling center; Cooling load; Cooling load temperature difference calculation method; Cooling tower ...
Cooling capacity is the measure of a cooling system's ability to remove heat. [1] It is equivalent to the heat supplied to the evaporator/boiler part of the refrigeration cycle and may be called the "rate of refrigeration" or "refrigeration capacity".
The above equation only takes into account the temperature differences and ignores two important parameters, being 1) solar radiative flux; and 2) infrared exchanges from the sky. The concept of T sol-air was thus introduced to enable these parameters to be included within an improved calculation. The following formula results:
The peak heating or cooling load used to select the equipment for a system (such as a heat pump) and to design the air distribution system (supply air diffusers, return air grilles, and the duct system). Design loads are based on standard or accepted conditions for a given locality (a design day).
Water is inexpensive, non-toxic, and available over most of the earth's surface.Liquid cooling offers higher thermal conductivity than air cooling. Water has unusually high specific heat capacity among commonly available liquids at room temperature and atmospheric pressure allowing efficient heat transfer over distance with low rates of mass transfer.