R-407C is a mixture of hydrofluorocarbons used as a refrigerant. It is a zeotropic blend of difluoromethane (R-32), pentafluoroethane (R-125), and 1,1,1,2-tetrafluoroethane (R-134a). Difluoromethane serves to provide the heat capacity, pentafluoroethane decreases flammability, tetrafluoroethane reduces pressure. [1] R-407C cylinders are colored ...
Discharge pressure (also called high side pressure or head pressure) is the pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. The discharge pressure is affected by several factors: size and speed of the condenser fan, condition and cleanliness of the condenser coil, and the size of the ...
Refrigerant concentration limit / immediately dangerous to life or health in parts per million (volume per volume) and grams per cubic meter Molecular mass in atomic mass units Normal boiling points for pure substances, bubble and dew points for zeotropic blends, or normal boiling point and azeotropic temperature for the azeotropic blends, at ...
A vapor compression cycle is used in most household refrigerators, refrigerator–freezers and freezers. In this cycle, a circulating refrigerant such as R134a enters a compressor as low-pressure vapor at or slightly below the temperature of the refrigerator interior. The vapor is compressed and exits the compressor as high-pressure superheated ...
A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.
At the start of the thermodynamic cycle the refrigerant enters the compressor as a low pressure and low temperature vapor. In heat pumps, this refrigerant is typically R32 refrigerant or R290 refrigerant. Then the pressure is increased and the refrigerant leaves as a higher temperature and higher pressure superheated gas.
This is an auto-cascade process with two different refrigerants. The high-temperature refrigerant (red) condenses in the air condenser and is then separated and evaporated to cool the heat exchanger, which condenses the low-temperature refrigerant (blue). Purple signifies a mixture of both refrigerants.
Common absorption refrigerators use a refrigerant with a very low boiling point (less than −18 °C (0 °F)) just like compressor refrigerators.Compression refrigerators typically use an HCFC or HFC, while absorption refrigerators typically use ammonia or water and need at least a second fluid able to absorb the coolant, the absorbent, respectively water (for ammonia) or brine (for water).