When.com Web Search

  1. Ad

    related to: 407 refrigerant pressure temperature chart high side low side hvac

Search results

  1. Results From The WOW.Com Content Network
  2. R-407C - Wikipedia

    en.wikipedia.org/wiki/R-407C

    R-407C is a mixture of hydrofluorocarbons used as a refrigerant. It is a zeotropic blend of difluoromethane (R-32), pentafluoroethane (R-125), and 1,1,1,2-tetrafluoroethane (R-134a). Difluoromethane serves to provide the heat capacity, pentafluoroethane decreases flammability, tetrafluoroethane reduces pressure. [1] R-407C cylinders are colored ...

  3. Cascade refrigeration - Wikipedia

    en.wikipedia.org/wiki/Cascade_refrigeration

    The evaporation-condensation temperatures of each cycle are sequentially lower with some overlap to cover the total temperature drop desired, with refrigerants selected to work efficiently in the temperature range they cover. The low temperature system removes heat from the space to be cooled using an evaporator, and transfers it to a heat ...

  4. List of refrigerants - Wikipedia

    en.wikipedia.org/wiki/List_of_refrigerants

    Critical temperature in degrees Celsius; Absolute critical pressure in kilopascals; Since over 100,000 refrigerant blends are possible, [2] this list should only have notable refrigerants and refrigerant blends.

  5. Heat pump and refrigeration cycle - Wikipedia

    en.wikipedia.org/wiki/Heat_pump_and...

    At the start of the thermodynamic cycle the refrigerant enters the compressor as a low pressure and low temperature vapor. In heat pumps, this refrigerant is typically R32 refrigerant or R290 refrigerant. Then the pressure is increased and the refrigerant leaves as a higher temperature and higher pressure superheated gas.

  6. Vapor-compression refrigeration - Wikipedia

    en.wikipedia.org/wiki/Vapor-compression...

    A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.

  7. Discharge pressure - Wikipedia

    en.wikipedia.org/wiki/Discharge_pressure

    Discharge pressure (also called high side pressure or head pressure) is the pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. The discharge pressure is affected by several factors: size and speed of the condenser fan, condition and cleanliness of the condenser coil, and the size of the ...

  8. R-407A - Wikipedia

    en.wikipedia.org/wiki/R-407A

    R-407A was developed as a close match to R-22's capacities and flow rates, making it well suited as an energy efficient retrofit for R-22 in medium and low temperature refrigeration systems for supermarket and food storage applications, but not for air conditioning systems or those with flooded evaporators. [2] It must be used with synthetic ...

  9. Difluoromethane - Wikipedia

    en.wikipedia.org/wiki/Difluoromethane

    Difluoromethane is a molecule used as refrigerant that has prominent heat transfer and pressure drop performance, both in condensation and vaporization. [6] It has a 100-year global warming potential (GWP) of 675 times that of carbon dioxide, and an atmospheric lifetime of nearly 5 years. [ 7 ]