When.com Web Search

  1. Ads

    related to: what to grab when evacuating a fire sprinkler line backflow valve is required

Search results

  1. Results From The WOW.Com Content Network
  2. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices , [ 1 ] [ 2 ] reduced pressure zone assemblies (RPZA), [ 3 ] or reduced pressure ...

  3. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap. An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.

  4. Glossary of firefighting equipment - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_firefighting...

    Type of sprinkler system where sprinkler heads do not have individual valves, and the water (or other extinguishing agent) is disbursed from all sprinkler heads simultaneously when a central (or zoned) valve is triggered by a sensor (or manually). This is typically reserved for industrial areas where rapid fire spread must be prevented at the ...

  5. Backflow - Wikipedia

    en.wikipedia.org/wiki/Backflow

    A recent introduction to the UK has been the Reduced Pressure Zone (RPZ) valve, a form of double check valve where the intervening zone is drained and normally kept empty. [1] If the downstream valve leaks and permits backflow, this will drain out through the vent rather than building up pressure against the upstream valve.

  6. Glossary of firefighting - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_firefighting

    Backflow preventer: Automatic valve used in hose accessories to ensure water flows only in one direction. Used in permanent fire department connections (FDC) to sprinklers and dry standpipes, as well as portable devices used in firefighting. Backstretching: Laying a supply line from the vicinity of the fire structure to a hydrant. (Typically ...

  7. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...

  8. What Would You Grab If Your House Were on Fire? - AOL

    www.aol.com/news/2012-05-08-what-would-you-grab...

    During an evacuation, it might be hard to cart off a sculpture while wrangling dogs and kids. The same goes for computer data. Back up your hard drive frequently and store it in the safe, in the ...

  9. Double check valve - Wikipedia

    en.wikipedia.org/wiki/Double_check_valve

    A double check valve or double check assembly (DCA) is a backflow prevention device designed to protect water supplies from contamination. [1] It is different from the two-way check valves (sometimes erroneously referred to as double check valves) used in air brake systems on heavy trucks which select from the highest pressure source.