  1. Results From The WOW.Com Content Network
  2. 10–20 system (EEG) - Wikipedia

    en.wikipedia.org/wiki/10–20_system_(EEG)

    The Fp2, F8, T4, T6, and O2 electrodes are placed at intervals of 5%, 10%, 10%, 10%, 10%, and 5%, respectively, measured above the right ear, from front (Fpz) to back (Oz). The same is done for the odd-numbered electrodes on the left side, to complete the full circumference. Measurement methods for placement of the F3, F4, P3, and P4 points differ.

  3. Lewis lead - Wikipedia

    en.wikipedia.org/wiki/Lewis_lead

    Electrode placement for Lewis lead; RL electrode (green), not shown, remains on leg . A Lewis Lead (also called the S5 lead) is a modified ECG lead used to detect atrial flutter waves when atrial flutter is suspected clinically, based on signs and symptoms, but is not definitely demonstrated on the standard 12 lead ECG.

  4. Nerve conduction study - Wikipedia

    en.wikipedia.org/wiki/Nerve_conduction_study

    Electrode placement: Surface electrodes are strategically placed on the skin over the nerve being tested and on a muscle it supplies or further along the path of that same nerve. [10] These electrodes record the nerve's electrical response and are referred to as surface recording electrodes. [ 10 ]

  5. Electroencephalography - Wikipedia

    en.wikipedia.org/wiki/Electroencephalography

    An EEG recording setup using the 10-10 system of electrode placement. EEG is the gold standard diagnostic procedure to confirm epilepsy.The sensitivity of a routine EEG to detect interictal epileptiform discharges at epilepsy centers has been reported to be in the range of 29–55%. [8]

  6. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    The limb electrodes can be far down on the limbs or close to the hips/shoulders as long as they are placed symmetrically. [30] Placement of American-color-coded ECG electrodes (using a 5-electrode yoke) Placement of European-color-coded ECG electrodes (using a 10-electrode yoke) Placement of the precordial electrodes

  7. Evoked potential - Wikipedia

    en.wikipedia.org/wiki/Evoked_potential

    Electrode placement is extremely important to elicit a good VEP response free of artifact. In a typical (one channel) setup, one electrode is placed 2.5 cm above the inion and a reference electrode is placed at Fz. For a more detailed response, two additional electrodes can be placed 2.5 cm to the right and left of Oz.

  8. Einthoven's triangle - Wikipedia

    en.wikipedia.org/wiki/Einthoven's_triangle

    Lead II — This axis goes from the right arm to the left leg, with the negative electrode on the shoulder and the positive one on the leg. This results in a +60 degree angle of orientation. [4] = Lead III — This axis goes from the left shoulder (negative electrode) to the right or left leg (positive electrode). This results in a +120 degree ...

  9. Defibrillation - Wikipedia

    en.wikipedia.org/wiki/Defibrillation

    Resuscitation electrodes are placed according to one of two schemes. The anterior-posterior scheme is the preferred scheme for long-term electrode placement. One electrode is placed over the left precordium (the lower part of the chest, in front of the heart). The other electrode is placed on the back, behind the heart in the region between the ...