When.com Web Search

  1. Ad

    related to: pulsed amperometric detector principle of design ppt free

Search results

  1. Results From The WOW.Com Content Network
  2. Amperometry - Wikipedia

    en.wikipedia.org/wiki/Amperometry

    Any analyte that can be oxidized or reduced is a candidate for amperometric detection. The simplest form of amperometric detection is single-potential, or direct current (DC), amperometry. A voltage (potential) is applied between two electrodes positioned in the column effluent. The measured current changes as an electroactive analyte is ...

  3. Charged aerosol detector - Wikipedia

    en.wikipedia.org/wiki/Charged_Aerosol_Detector

    The charged aerosol detector (CAD) is a detector used in conjunction with high-performance liquid chromatography (HPLC) and ultra high-performance liquid chromatography (UHPLC) to measure the amount of chemicals in a sample by creating charged aerosol particles which are detected using an electrometer.

  4. Chronoamperometry - Wikipedia

    en.wikipedia.org/wiki/Chronoamperometry

    Double-pulsed chronoamperometry waveform showing integrated region for charge determination.. In electrochemistry, chronoamperometry is an analytical technique in which the electric potential of the working electrode is stepped and the resulting current from faradaic processes occurring at the electrode (caused by the potential step) is monitored as a function of time.

  5. Voltammetry - Wikipedia

    en.wikipedia.org/wiki/Voltammetry

    Differential pulse voltammetry: An electrochemical technique similar to normal pulse voltammetry but the applied base potential is increased or decreased steadily, and the pulse height: base height ratio is kept constant. In DPV, measurements of current are taken twice during each drop, first immediately before the pulse and second before the ...

  6. Multichannel analyzer - Wikipedia

    en.wikipedia.org/wiki/Multichannel_analyzer

    Pulse-Height Analyzer Principle: Three pulses, 1, 2, and 3 are detected at different times t. Two discriminators emit a counting signal if their set voltage threshold is exceeded by a pulse. Pulse 2 triggers the Lower Level E L but not the Upper Level E U. Pulse 2 is thus counted into the spectral region denoted as P.

  7. Insulation monitoring device - Wikipedia

    en.wikipedia.org/wiki/Insulation_monitoring_device

    An insulation monitoring device monitors the ungrounded system between an active phase conductor and earth.It is intended to give an alert (light and sound) or disconnect the power supply when the resistance between the two conductors drops below a set value, usually 50 kΩ (sample of IEC standard for medical applications).

  8. Pirani gauge - Wikipedia

    en.wikipedia.org/wiki/Pirani_gauge

    A special form of the Pirani gauge is the pulsed Pirani vacuum gauge where the sensor wire is not operated at a constant temperature, but is cyclically heated up to a certain temperature threshold by an increasing voltage ramp. When the threshold is reached, the heating voltage is switched off and the sensor cools down again.

  9. Potentiometric sensor - Wikipedia

    en.wikipedia.org/wiki/Potentiometric_sensor

    Therefore, type I and type II sensors have the same design with gas electrodes combined with metal and an electrolyte where oxidized or reduced ions can be electrochemically equilibrated through the electrochemical cell. In the third type of electrochemical sex, auxiliary phases are added to the electrodes to enhance the selectivity and stability.