This type of construction is most often seen in warmer climates, where ground freezing and thawing is less of a concern and where there is no need for heat ducting underneath the floor. That being said, Frost Protected Shallow Foundations (or FPSF) which are used in areas of potential frost heave, are a form of slab-on-grade foundation. [4]
A crawl space or crawlspace is an unoccupied, unfinished, narrow space within a building, between the ground and the first (or ground) floor. The crawl space is so named because there is typically only enough room to crawl rather than stand; anything larger than about 1 to 1.5 metres (3 ft 3 in to 4 ft 11 in) and beneath the ground floor would ...
In many domestic and industrial buildings, a thick concrete slab supported on foundations or directly on the subsoil, is used to construct the ground floor. These slabs are generally classified as ground-bearing or suspended. A slab is ground-bearing if it rests directly on the foundation, otherwise the slab is suspended. [3]
Foundation with pipe fixtures coming through the sleeves. In engineering, a foundation is the element of a structure which connects it to the ground or more rarely, water (as with floating structures), transferring loads from the structure to the ground. Foundations are generally considered either shallow or deep. [1]
Lift slab construction (also called the Youtz-Slick Method) is a method of constructing concrete buildings by casting the floor or roof slab on top of the previous slab and then raising (jacking) the slab up with hydraulic jacks. This method of construction allows for a large portion of the work to be completed at ground level, negating the ...
Stuart [1] was the first pioneer to study the interference phenomenon of closely spaced surface strip footing. He examined the effect of footing interference on ultimate bearing capacity of strip footings by theoretical analysis using limit equilibrium method, assuming a non-linear failure surface wherein the cross-section composed of logarithmic spiral and straight line portion tangent to the ...
Waffle slab foundations adhere to International Building Code requirements. By 2008, most states put into effect the changes adopted in the 2006 IBC and, in regards to foundations, the on-grade mat foundation has become a more attractive design because, as an engineered system, it already accommodates the 2008 design recommendations, and required no major modifications to bring it into compliance.
The original foundation isn't strong or stable enough. The usage of the structure has changed. The properties of the soil supporting the foundation may have changed (possibly through subsidence) or were mischaracterized during design. The construction of nearby structures necessitates the excavation of soil supporting existing foundations.