Figure 1: Schematic layout of a White-light Interferometer. A CCD image sensor like those used for digital photography is placed at the point where the two images are superimposed. A broadband “white light” source is used to illuminate the test and reference surfaces. A condenser lens collimates the light from the broadband light source.
Figure 3. White light interferometric microscope. White-light interferometry scanning (WLS) systems capture intensity data at a series of positions along the vertical axis, determining where the surface is located by using the shape of the white-light interferogram, the localized phase of the interferogram, or a combination of both shape and phase.
Diffraction-grating interferometer (white light) Double-slit interferometer; Dual-polarization interferometry; Fabry–Pérot interferometer; Fizeau interferometer; Fourier-transform interferometer; Fresnel interferometer (e.g. Fresnel biprism, Fresnel mirror or Lloyd's mirror) Fringes of Equal Chromatic Order interferometer (FECO) Gabor hologram
White light interferometry is commonly used for detecting deformations of the wafer surface based on optical measurements. Low-coherence light from a white light source passes through the optical top wafer, e.g. glass wafer, to the bond interface. Usually there are three different white light interferometers: diffraction grating interferometers
Figure 1. The light path through a Michelson interferometer.The two light rays with a common source combine at the half-silvered mirror to reach the detector. They may either interfere constructively (strengthening in intensity) if their light waves arrive in phase, or interfere destructively (weakening in intensity) if they arrive out of phase, depending on the exact distances between the ...
DHM performs static measurements of 3D surface topography as many other 3D optical profilometers (white light interferometers, confocal, focus variation, ... ). It enables to retrieve, roughness and shape of many surfaces. [32] [33] [34] Use of multiple wavelengths enable to overcome the l/4 limit of traditional phase shifting interferometers ...
SCORE is especially used as detection method in bio- and chemosensors. It is a label-free technique like Reflectometric interference spectroscopy (RIfS), Bio-layer Interferometry (BLI) and Surface plasmon resonance (SPR), which allows time-resolved observation of binding events on the sensor surface without the use of fluorescence or radioactive labels.
Michelson interferometers using a white light source White light has a tiny coherence length and is difficult to use in a Michelson (or Mach–Zehnder ) interferometer. Even a narrowband (or "quasi-monochromatic") spectral source requires careful attention to issues of chromatic dispersion when used to illuminate an interferometer.