  1. Results From The WOW.Com Content Network
  2. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    Using metric units, the volumetric flow rate of a nozzle is given by =, [1] [2] where q is the flow rate in litres per minute ( l/min ), p is the pressure at the nozzle in bar and K is the K-factor is given in units of (/) /.

  3. 2,2-Dichloro-1,1,1-trifluoroethane - Wikipedia

    en.wikipedia.org/wiki/2,2-Dichloro-1,1,1-trifluo...

    2,2-Dichloro-1,1,1-trifluoroethane or HCFC-123 is considered as an alternative to CFC-11 in low pressure refrigeration and HVAC systems, and should not be used in foam blowing processes or solvent applications. It is also the primary component of the Halotron I fire-extinguishing mixture.

  4. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance.

  5. North American Fire Hose Coupler Incompatibilities - Wikipedia

    en.wikipedia.org/wiki/North_American_Fire_Hose...

    At its annual convention at Dallas, TX, the NFPA formally adopted a standard with 2 + 12-inch hose with 7.5 threads per inch as the primary standard, with additional sizes of 3 and 3.5 inches (each with 6 threads per inch) and a 4.5 inch coupling with 4 threads per inch, with the fire hydrant standard specifying one 4.5 inch port and two 2 ...

  6. Hazen–Williams equation - Wikipedia

    en.wikipedia.org/wiki/Hazen–Williams_equation

    The Hazen–Williams equation is an empirical relationship that relates the flow of water in a pipe with the physical properties of the pipe and the pressure drop caused by friction. It is used in the design of water pipe systems [1] such as fire sprinkler systems, [2] water supply networks, and irrigation systems.

  7. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    With C v = 1.0 and 200 psia inlet pressure, the flow is 100 standard cubic feet per minute (scfm). The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 ...

  8. Glossary of firefighting equipment - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_firefighting...

    Fire hose used to apply water or other fire fighting agent directly to a fire or burning substance. Typically of 2 + 12 inches (64 mm) diameter or less in the United States. Historically 1.5 inch hose was the primary initial attack line but has been supplanted in most of the US by 1.75-inch-diameter (44 mm) hose that carries 175 gallons ...

  9. Hard suction hose - Wikipedia

    en.wikipedia.org/wiki/Hard_suction_hose

    5-inch (13 cm) flex suction hose with Storz fittings, mounted on an engine. Flexible suction hose (Flex suction or suction hose), not to be confused with hard suction hose in U.S., is a specific type of fire hose used in drafting operations, when a fire engine uses a vacuum to draw water from a portable water tank, pool, or other static water source.