Because many definitions of standard temperature and pressure differ in temperature significantly from standard laboratory temperatures (e.g. 0 °C vs. ~28 °C), reference is often made to "standard laboratory conditions" (a term deliberately chosen to be different from the term "standard conditions for temperature and pressure", despite its ...
Due to the variability of the definition and the consequences of ambiguity, it is best engineering practice to state what standard conditions are used when communicating a "standard" flow value. In countries using the SI metric system of units, the term " normal cubic metre " (Nm 3 ) is very often used to denote gas volumes at some normalized ...
Base conditions, also known as standard conditions, consist of a specified absolute pressure and temperature. To ensure accuracy, it is important to refer to base conditions when measuring the volume of a sample of liquid or gas. This applies to both static measurement and flow measurement.
The standard liter per minute (SLM or SLPM) is a unit of (molar or) mass flow rate of a gas at standard conditions for temperature and pressure (STP), which is most commonly practiced in the United States, whereas European practice revolves around the normal litre per minute (NLPM). [1]
A standard cubic foot (scf) is a unit representing the amount of gas (such as natural gas) contained in a volume of one cubic foot at reference temperature and pressure conditions. It is the unit commonly used when following the customary system, a collection of standards set by the National Institute of Standards and Technology.
Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.
The standard state of a material (pure substance, mixture or solution) is a reference point used to calculate its properties under different conditions.A degree sign (°) or a superscript Plimsoll symbol (⦵) is used to designate a thermodynamic quantity in the standard state, such as change in enthalpy (ΔH°), change in entropy (ΔS°), or change in Gibbs free energy (ΔG°).
A normal cubic meter (Nm 3) is the metric expression of gas volume at standard conditions and it is usually (but not always) defined as being measured at 0 °C and 1 atmosphere of pressure. A standard cubic foot (scf) is the USA expression of gas volume at standard conditions and it is often ( but not always ) defined as being measured at 60 ...