When.com Web Search

  1. Ads

    related to: load range vs chart of size difference equation pdf converter word

Search results

  1. Results From The WOW.Com Content Network
  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  3. Range (aeronautics) - Wikipedia

    en.wikipedia.org/wiki/Range_(aeronautics)

    The range equation reduces to: = where =; here is the specific heat constant of air 287.16 J/kg K (based on aviation standards) and = / = (derived from = and = +). c p {\displaystyle c_{p}} and c v {\displaystyle c_{v}} are the specific heat capacities of air at constant pressure and constant volume respectively.

  4. Paris' law - Wikipedia

    en.wikipedia.org/wiki/Paris'_law

    In a 1961 paper, P. C. Paris introduced the idea that the rate of crack growth may depend on the stress intensity factor. [4] Then in their 1963 paper, Paris and Erdogan indirectly suggested the equation with the aside remark "The authors are hesitant but cannot resist the temptation to draw the straight line slope 1/4 through the data" after reviewing data on a log-log plot of crack growth ...

  5. Compressive strength - Wikipedia

    en.wikipedia.org/wiki/Compressive_strength

    ´ =, where F is load applied [N] and A is area [m 2]. As stated, the area of the specimen varies on compression. In reality therefore the area is some function of the applied load i.e. A = f (F). Indeed, stress is defined as the force divided by the area at the start of the experiment.

  6. Design load - Wikipedia

    en.wikipedia.org/wiki/Design_load

    A crane's rated load is its Safe Working Load (SWL) and the design load (DL) is, (p 90) [1] = The dynamic lift factor for offshore cranes in the range 10 kN < SWL ≤ 2500 kN is not less than =.(p 84) [1] Thus for a crane with a SWL of 2000 kN (~200 tonne) its design load is not less than, = = The minimum breaking load (MBL) for the combined capacity of reeves of a steel wire hoisting rope ...

  7. Load profile - Wikipedia

    en.wikipedia.org/wiki/Load_Profile

    In a power system, a load curve or load profile is a chart illustrating the variation in demand/electrical load over a specific time. Generation companies use this information to plan how much power they will need to generate at any given time. A load duration curve is similar to a load curve. The information is the same but is presented in a ...

  8. Crack growth equation - Wikipedia

    en.wikipedia.org/wiki/Crack_growth_equation

    Figure 1: Typical plot of crack growth rate versus the stress intensity range. The Paris–Erdogan equation fits the central linear region of Regime B. A crack growth equation is used for calculating the size of a fatigue crack growing from cyclic loads. The growth of a fatigue crack can result in catastrophic failure, particularly in the case ...

  9. Euler's critical load - Wikipedia

    en.wikipedia.org/wiki/Euler's_critical_load

    The critical load is the greatest load that will not cause lateral deflection (buckling). For loads greater than the critical load, the column will deflect laterally. The critical load puts the column in a state of unstable equilibrium. A load beyond the critical load causes the column to fail by buckling. As the load is increased beyond the ...