When.com Web Search

  1. Ads

    related to: live load for residential floor

Search results

  1. Results From The WOW.Com Content Network
  2. Structural load - Wikipedia

    en.wikipedia.org/wiki/Structural_load

    Live loads, sometimes also referred to as probabilistic loads, include all the forces that are variable within the object's normal operation cycle not including construction or environmental loads. Roof and floor live loads are produced during maintenance by workers, equipment and materials, and during the life of the structure by movable ...

  3. Eurocode 1: Actions on structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_1:_Actions_on...

    In the Eurocode series of European standards (EN) related to construction, Eurocode 1: Actions on structures (abbreviated EN 1991 or, informally, EC 1) describes how to design load-bearing structures. It includes characteristic values for various types of loads and densities for all materials which are likely to be used in construction.

  4. Structural engineering theory - Wikipedia

    en.wikipedia.org/wiki/Structural_engineering_theory

    A typical load case for design for serviceability (characteristic load cases; SLS) is: 1.0 x Dead Load + 1.0 x Live Load. Different load cases would be used for different loading conditions. For example, in the case of design for fire a load case of 1.0 x Dead Load + 0.8 x Live Load may be used, as it is reasonable to assume everyone has left ...

  5. Open web steel joist - Wikipedia

    en.wikipedia.org/wiki/Open_web_steel_joist

    The main function of an OWSJ is to provide direct support for roof or floor deck and to transfer the load imposed on the deck to the structural frame i.e. beam and column. In order to accurately design an OWSJ, engineers consider the joist span between bearing points, joist spacing, slope, live loads , dead loads , collateral loads, seismic ...

  6. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    The most common three-phase system will have three hot legs, 208 V to each other and 120 V each to the neutral. An older, but still widely used, high-leg delta system uses three phases with 240 volts phase-to-phase for motor loads, and 120 volts for lighting loads by use of a center-tapped transformer; two of the phases are 120 volts to neutral ...

  7. Curtain wall (architecture) - Wikipedia

    en.wikipedia.org/wiki/Curtain_wall_(architecture)

    In tests, standard curtain wall systems are typically able to withstand up to three inches (76 mm) of relative floor movement without glass breakage or water leakage. Snow load. Snow loads and live loads are not typically an issue in curtain walls, since curtain walls are designed to be vertical or slightly inclined. If the slope of a wall ...

  8. Limit state design - Wikipedia

    en.wikipedia.org/wiki/Limit_state_design

    In determining the specific magnitude of the factors, more deterministic loads (e.g., dead load - the weight of the structure and permanent attachments like walls, floor treatments, ceiling finishes) are given lower factors (for example 1.4) than highly variable loads like earthquake, wind, or live (occupancy) loads (1.6).

  9. Structural support - Wikipedia

    en.wikipedia.org/wiki/Structural_support

    External loads (actions of other bodies) that act on buildings cause internal forces (forces and couples by the rest of the structure) in building support structures. Supports can be either at the end or at any intermediate point along a structural member or a constituent part of a building and they are referred to as connections, joints or ...