When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Intrinsic safety - Wikipedia

    en.wikipedia.org/wiki/Intrinsic_safety

    In signal and control circuits that can operate with low currents and voltages, the intrinsic safety approach simplifies circuits and reduces installation cost over other protection methods. Areas with dangerous concentrations of flammable gases or dust are found in applications such as petrochemical refineries and mines.

  3. Electrical equipment in hazardous areas - Wikipedia

    en.wikipedia.org/wiki/Electrical_equipment_in...

    Unlike ATEX which uses numbers to define the safety "Category" of equipment (namely 1, 2, and 3), the IEC continued to utilise the method used for defining the safe levels of intrinsic safety namely "a" for zone 0, "b" for zone 1 and "c" for zone 2 and apply this Equipment Level of Protection to all equipment for use in hazardous areas since ...

  4. Inherent safety - Wikipedia

    en.wikipedia.org/wiki/Inherent_safety

    (Kletz originally used the term intrinsically safe in 1978, but as this had already been used for the special case of electronic equipment in potentially flammable atmospheres, only the term inherent was adopted. Intrinsic safety may be considered a special subset of inherent safety). In 2010 the American Institute of Chemical Engineers ...

  5. Current limiting - Wikipedia

    en.wikipedia.org/wiki/Current_limiting

    The safety benefit of reducing the power delivered to a short circuit in the load is proportional to the operating current limit. Foldback current limiting is most likely to be found in a switch-mode power supply when it is a component in a product that is independently certified to meet regional safety standards. [2]

  6. Electrical safety testing - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_testing

    MOPP safety standards aim to set basic safety requirements for medical electrical equipment. "With hazardous voltages present in a system a robust and reliable approach to isolation is needed such that multiple and un-related insulation system failures would need to occur before an operator or patient is put at risk.

  7. Isolated ground - Wikipedia

    en.wikipedia.org/wiki/Isolated_ground

    The primary reason for the use of isolated grounds (IG) is to provide a noise-free ground return, separate from the equipment grounding (EG) return. The EG circuit includes all of the metal conduit, outlet boxes, and metal enclosures that contain the wiring and must be grounded to provide a safe return path in case of fault currents.

  8. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  9. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    Calculation of the required breaking capacity involves determining the supply impedance and voltage. Supply impedance is calculated from the impedance of the elements making up the supply system. Customers of an electrical supply utility can request the maximum value of prospective short-circuit current available at their point of supply.