This term is normally used in short circuit conditions and the values are used to perform co-ordination studies in electrical networks. I 2 t parameters are provided by charts in manufacturer data sheets for each fuse family. For coordination of fuse operation with upstream or downstream devices, both melting I 2 t and clearing I 2 t are
The Western Electric rules are decision rules in statistical process control for detecting out-of-control or non-random conditions on control charts. [1] Locations of the observations relative to the control chart control limits (typically at ±3 standard deviations) and centerline indicate whether the process in question should be investigated for assignable causes.
The ¯ and R chart plots the mean value for the quality characteristic across all units in the sample, ¯, plus the range of the quality characteristic across all units in the sample as follows: R = x max - x min. The normal distribution is the basis for the charts and requires the following assumptions: The quality characteristic to be ...
Sheet resistance is a special case of resistivity for a uniform sheet thickness. Commonly, resistivity (also known as bulk resistivity, specific electrical resistivity, or volume resistivity) is in units of Ω·m, which is more completely stated in units of Ω·m 2 /m (Ω·area/length). When divided by the sheet thickness (m), the units are Ω ...
In electrical engineering, IEC 60269 is a set of technical standards for low-voltage power fuses. [1] The standard is in four volumes, which describe general requirements, fuses for industrial and commercial applications, fuses for residential applications, and fuses to protect semiconductor devices.
The device may not return to its original resistance value; it will most likely stabilize at a significantly higher resistance (up to 4 times initial value). It could take hours, days, weeks or even years for the device to return to a resistance value similar to its original value, if at all. [8] A PPTC device has a current rating and a voltage ...
The units of specific contact resistivity are typically therefore in ohm-square metre, or Ω⋅m 2. When the current is a linear function of the voltage, the device is said to have ohmic contacts. Inductive and capacitive methods could be used in principle to measure an intrinsic impedance without the complication of contact resistance.
Calculation of the required breaking capacity involves determining the supply impedance and voltage. Supply impedance is calculated from the impedance of the elements making up the supply system. Customers of an electrical supply utility can request the maximum value of prospective short-circuit current available at their point of supply.