Search results
Results From The WOW.Com Content Network
Modern micrometer with a reading of 1.639 ± 0.005 mm. Assuming no zero error, this is also the measurement. (One may need to enlarge the image to read it.) Outside, inside, and depth micrometers. The outside micrometer has a unit conversion chart between fractional and decimal inch measurements etched onto the frame
Vernier caliper scales; main at top, vernier at bottom. It reads 3.58 ± 0.02 mm by adding 3.00 mm (left red mark) on the fixed main scale to vernier 0.58 mm (right red mark). The main scale reading is that to the left of the zero on the vernier scale. The vernier reading is found by locating the best aligned lines between the two scales.
An inside micrometer or vernier bore gauge measures a bore directly. The gauge has three symmetrical anvils that protrude from the gauge body that are connected to the dial or micrometer mechanism. As the knob is rotated it moves the anvils in or out with respect to the measurements.
These are "absolute" errors and absolute errors add, so the length reading is then bounded by plus/minus the length corresponding to the full width of the smallest interval on the vernier scale (0.005 cm). Assuming no systematics affect the measurement (the instrument works perfectly), a complete measurement would then read 2.462 cm ± 0.005 cm.
Length (system unit unit-code symbol or abbrev. notes sample default conversion combination output units SI: megametre: Mm Mm US spelling: megameter 1.0 Mm (620 mi) kilometre
A metallic carriage clamped to a spring-loaded bar slides with its attached vernier and reading lens along an inlaid strip of metal scale. The scale is divided in half millimeters. Fine adjustments are made by means of a micrometer screw for taking accurate reading. Both vernier reading to 0.01mm or 0.02mm.
The main scale reading is the rightmost graduation that is to the left of the zero on the vernier scale. The vernier reading is found by locating the best aligned lines between the two scales. The 0.02 mm engraving indicates the caliper's accuracy and is the "Vernier constant" for this scale. He was born in Ornans, France, in 1580. He was ...
The reading is taken from the scale marked next to the grooves, in dimensionless "Hegman units" (or National Standard units; NS) and/or mils or micrometres. [5] Hegman units are defined in terms of an inverted size scale as shown below: [6] Hegman Grind Gage and doctor blade Paint sample at top of Hegman Hegman after paint drawdown