A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
Standard solutions are commonly used to determine the concentration of an analyte species via calibration curve. A calibration curve is obtained by measuring a series of standard solutions with known concentrations, which can be used to determine the concentration of an unknown sample using linear regression analysis. [10]
Wiggle matching, also known as carbon–14 wiggle-match dating (WMD) is a dating method that uses the non-linear relationship between 14 C age and calendar age to match the shape of a series of closely sequentially spaced 14 C dates with the 14 C calibration curve.
The calibration curve that does not use the internal standard method ignores the uncertainty between measurements. The coefficient of determination (R 2) for this plot is 0.9985. In the calibration curve that uses the internal standard, the y-axis is the ratio of the nickel signal to the yttrium signal.
As of 2020, this is the most recent version of the standard calibration curve. The diagonal line shows where the curve would lie if radiocarbon ages and calendar ages were the same. [84] Over the next thirty years many calibration curves were published using a variety of methods and statistical approaches. [42]
The calibration curve for the southern hemisphere is known as the SHCal as opposed to the IntCal for the northern hemisphere; the most recent version was published in 2020. There is also a curve for the period after 1955, where radiocarbon levels were artificially inflated due to atomic bomb testing, varying with latitude, known as Bomb Cal ...
Using the calibration curve method, the analyst can calibrate the spectrometer with a pure silver aqueous solutions, and use the calibration graph to determine the amount of silver present in the waste samples. This method, however, assumes the pure aqueous solution of silver and a photographic waste sample have the same matrix and therefore ...
[3] [4] The most common approach for accounting for matrix effects is to build a calibration curve using standard samples with known analyte concentration and which try to approximate the matrix of the sample as much as possible. [2] This is especially important for solid samples where there is a strong matrix influence. [5]