  1. Results From The WOW.Com Content Network
  2. Celloscope automated cell counter - Wikipedia

    en.wikipedia.org/wiki/Celloscope_automated_cell...

    Celloscope automated cell counter was developed in the 1950s for enumeration of erythrocytes, leukocytes, and thrombocytes in blood samples. [1] Together with the Coulter counter, the Celloscope analyzer can be considered one of the predecessors of today's automated hematology analyzers, as the principle of the electrical impedance method is still utilized in cell counters installed in ...

  3. Coulter counter - Wikipedia

    en.wikipedia.org/wiki/Coulter_counter

    The Coulter counter is the commercial term for the technique known as resistive pulse sensing or electrical zone sensing. The apparatus is based on the Coulter principle named after its inventor, Wallace H. Coulter. A typical Coulter counter has one or more microchannels that separate two chambers containing electrolyte solutions.

  4. Sysmex XE-2100 - Wikipedia

    en.wikipedia.org/wiki/Sysmex_XE-2100

    Blood is sampled and diluted, and moves through a tube thin enough that cells pass by one at a time. Characteristics about the cell are measured using lasers (fluorescence flow cytometry) or electrical impedance. Because not everything about the cells can be measured at the same time, blood is separated into a number of different channels.

  5. Complete blood count - Wikipedia

    en.wikipedia.org/wiki/Complete_blood_count

    The Coulter principle uses electrical impedance measurements to count blood cells and determine their sizes; it is a technology that remains in use in many automated analyzers. Further research in the 1970s involved the use of optical measurements to count and identify cells, which enabled the automation of the white blood cell differential.

  6. Hematology analyzer - Wikipedia

    en.wikipedia.org/wiki/Hematology_analyzer

    Hematology analyzers are used to conduct a complete blood count (CBC), which is usually the first test requested by physicians to determine a patient's general health status. [5] A complete blood count includes red blood cell (RBC), white blood cell (WBC), hemoglobin, and platelet counts, as well as hematocrit levels.

  7. Automated analyser - Wikipedia

    en.wikipedia.org/wiki/Automated_analyser

    The passage of cells through the current changes the impedance between the terminals (the Coulter principle). [6] A lytic reagent is added to the blood solution to selectively lyse the red cells (RBCs), leaving only white cells (WBCs), and platelets intact. Then the solution is passed through a second detector.