When.com Web Search

  1. Ad

    related to: inductive load power factor

Search results

  1. Results From The WOW.Com Content Network
  2. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Power-factor correction increases the power factor of a load, improving efficiency for the distribution system to which it is attached. Linear loads with a low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the ...

  3. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    An inductive load consists of an iron-core reactive element which, when used in conjunction with a resistive load bank, creates a lagging power factor load. Typically, the inductive load will be rated at a numeric value 75% that of the corresponding resistive load such that when applied together a resultant 0.8 power factor load is provided.

  4. Induction motor - Wikipedia

    en.wikipedia.org/wiki/Induction_motor

    The power factor of induction motors varies with load, typically from about 0.85 or 0.90 at full load to as low as about 0.20 at no-load, [39] due to stator and rotor leakage and magnetizing reactances. [45]

  5. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    The full-load current of the motor is 10 A and the full-load power factor is 0.8. Required capacitance per phase if capacitors are connected in delta: Apparent power S = 3 E I = 1.73 ∗ 440 ∗ 10 = 7612 V A {\displaystyle S={\sqrt {3}}EI=1.73*440*10=7612VA}

  6. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    To avoid magnetic inrush, only for transformers with an air gap in the core, the inductive load needs to be synchronously connected near a supply voltage peak, in contrast with the zero-voltage switching, which is desirable to minimize sharp-edged current transients with resistive loads such as high-power heaters.

  7. Impedance matching - Wikipedia

    en.wikipedia.org/wiki/Impedance_matching

    However, the maximum power theorem does not apply to its "downstream" connection. That connection is an impedance bridging connection; it emulates a high-voltage, low-resistance source to maximize efficiency. On the power grid the overall load is usually inductive. Consequently, power factor correction is most commonly achieved with banks of ...

  8. Leading and lagging current - Wikipedia

    en.wikipedia.org/wiki/Leading_and_Lagging_Current

    Angle notation can easily describe leading and lagging current: . [1] In this equation, the value of theta is the important factor for leading and lagging current. As mentioned in the introduction above, leading or lagging current represents a time shift between the current and voltage sine curves, which is represented by the angle by which the curve is ahead or behind of where it would be ...

  9. Voltage regulation - Wikipedia

    en.wikipedia.org/wiki/Voltage_regulation

    Three power factor scenarios are shown, where (a) the line serves an inductive load so the current lags receiving end voltage, (b) the line serves a completely real load so the current and receiving end voltage are in phase, and (c) the line serves a capacitive load so the current leads receiving end voltage.