The NFPA 72 "covers the application, installation, location, performance, inspection, testing, and maintenance of fire alarm systems, supervising station alarm systems, public emergency alarm reporting systems, fire warning equipment and emergency communications systems (ECS), and their components."
New codes and standards introduced around 2010, especially the new UL Standard 2572, the US Department of Defense's UFC 4-021-01 Design and O&M Mass Notification Systems, and NFPA 72 2010 edition Chapter 24, have led fire alarm system manufacturers to expand their systems voice evacuation capabilities to support new requirements for mass ...
Metal alloy IBC tanks are also manufactured according to NFPA and UL142 certification standards for extensive storage of materials labelled as flammable and/or combustible. Intermediate bulk containers can be manufactured from various materials based on the requirements of the application or service the IBC will be used for.
The NFPA 72 standard uses the term Alarm Box, which could encompass a number of initiation mechanisms. [3] A few manual call points have been approved to UL/UL Canada standards. [4] [5] At the time of this writing, the pull station is still the most prominent design in this part of the world.
From NFPA 72, 2002 Edition: “7.4.2.1* To ensure that audible public mode signals are clearly heard, unless otherwise permitted by 7.4.2.2 through 7.4.2.5, they shall have a sound level at least 15 dB above the average ambient sound level or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater ...
Coded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel, which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset ...
A fire alarm box, fire alarm call box, or fire alarm pull box is a device used for notifying a fire department of a fire or a fire alarm activation. Typically installed on street corners or on the outside of commercial buildings in urban areas, they were the main means of summoning firefighters before the general availability of telephones.
The publication Life Safety Code, known as NFPA 101, is a consensus standard widely adopted in the United States. [according to whom?] It is administered, trademarked, copyrighted, and published by the National Fire Protection Association and, like many NFPA documents, is systematically revised on a three-year cycle.