When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour.

  3. Energy conversion efficiency - Wikipedia

    en.wikipedia.org/wiki/Energy_conversion_efficiency

    Most air conditioners have a COP of 2.3 to 3.5. [4] When talking about the efficiency of heat engines and power stations the convention should be stated, i.e., HHV (a.k.a. Gross Heating Value, etc.) or LCV (a.k.a. Net Heating value), and whether gross output (at the generator terminals) or net output (at the power station fence) are being ...

  4. Isobaric process - Wikipedia

    en.wikipedia.org/wiki/Isobaric_process

    Isobaric expansion of 2 cubic meters of air at 300 Kelvin to 4 cubic meters, causing the temperature to increase to 600 Kelvin while the pressure remains the same. In the first process example, a cylindrical chamber 1 m 2 in area encloses 81.2438 mol of an ideal diatomic gas of molecular mass 29 g mol −1 at 300 K. The surrounding gas is at 1 ...

  5. Thermal efficiency - Wikipedia

    en.wikipedia.org/wiki/Thermal_efficiency

    The efficiency of the Diesel cycle is dependent on r and γ like the Otto cycle, and also by the cutoff ratio, r c, which is the ratio of the cylinder volume at the beginning and end of the combustion process: [4] = () The Diesel cycle is less efficient than the Otto cycle when using the same compression ratio.

  6. Betz's law - Wikipedia

    en.wikipedia.org/wiki/Betz's_law

    In order to keep the wind moving through the turbine, there has to be some wind movement, however small, on the other side with some wind speed greater than zero. Betz's law shows that as air flows through a certain area, and as wind speed slows from losing energy to extraction from a turbine, the airflow must distribute to a wider area.

  7. NTU method - Wikipedia

    en.wikipedia.org/wiki/NTU_Method

    The number of transfer units (NTU) method is used to calculate the rate of heat transfer in heat exchangers (especially parallel flow, counter current, and cross-flow exchangers) when there is insufficient information to calculate the log mean temperature difference (LMTD). Alternatively, this method is useful for determining the expected heat ...

  8. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    A realistic indication of energy efficiency over an entire year can be achieved by using seasonal COP or seasonal coefficient of performance (SCOP) for heat. Seasonal energy efficiency ratio (SEER) is mostly used for air conditioning. SCOP is a new methodology which gives a better indication of expected real-life performance of heat pump ...

  9. Hampson–Linde cycle - Wikipedia

    en.wikipedia.org/wiki/Hampson–Linde_cycle

    The Hampson–Linde cycle differs from the Siemens cycle only in the expansion step. Whereas the Siemens cycle has the gas do external work to reduce its temperature, the Hampson–Linde cycle relies solely on the Joule–Thomson effect ; this has the advantage that the cold side of the cooling apparatus needs no moving parts.