When.com Web Search

  1. Ads

    related to: rms calculation calculator for dc generator unit price

Search results

  1. Results From The WOW.Com Content Network
  2. Motor constants - Wikipedia

    en.wikipedia.org/wiki/Motor_constants

    The rating of a brushless motor is the ratio of the motor's unloaded rotational speed (measured in RPM) to the peak (not RMS) voltage on the wires connected to the coils (the back EMF). For example, an unloaded motor of K v {\displaystyle K_{\text{v}}} = 5,700 rpm/V supplied with 11.1 V will run at a nominal speed of 63,270 rpm (= 5,700 rpm/V ...

  3. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  4. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Power Quality Analyzers, often referred to as Power Analyzers, make a digital recording of the voltage and current waveform (typically either one phase or three phase) and accurately calculate true power (watts), apparent power (VA) power factor, AC voltage, AC current, DC voltage, DC current, frequency, IEC61000-3-2/3-12 Harmonic measurement ...

  5. True RMS converter - Wikipedia

    en.wikipedia.org/wiki/True_RMS_converter

    The RMS value of an alternating current is also known as its heating value, as it is a voltage which is equivalent to the direct current value that would be required to get the same heating effect. For example, if 120 V AC RMS is applied to a resistive heating element it would heat up by exactly the same amount as if 120 V DC were applied.

  6. Harmonics (electrical power) - Wikipedia

    en.wikipedia.org/wiki/Harmonics_(electrical_power)

    In a normal alternating current power system, the current varies sinusoidally at a specific frequency, usually 50 or 60 hertz.When a linear time-invariant electrical load is connected to the system, it draws a sinusoidal current at the same frequency as the voltage, although not always in phase with the voltage).

  7. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    Notice also that using the root mean square voltage =, the expression for above takes the following more classic form: P T O T = 3 V 2 R {\displaystyle P_{TOT}={\frac {3V^{2}}{R}}} . The load need not be resistive for achieving a constant instantaneous power since, as long as it is balanced or the same for all phases, it may be written as