Search results

  1. Results From The WOW.Com Content Network
  2. Oil immersion - Wikipedia

    en.wikipedia.org/wiki/Oil_immersion

    An oil immersion objective is an objective lens specially designed to be used in this ... The numerical aperture of cedar tree oil objectives is generally around 1.3.

  3. Numerical aperture - Wikipedia

    en.wikipedia.org/wiki/Numerical_aperture

    Numerical aperture is commonly used in microscopy to describe the acceptance cone of an objective ... 1.33 for pure water, and typically 1.52 for immersion oil; [1] ...

  4. Immersion lithography - Wikipedia

    en.wikipedia.org/wiki/Immersion_lithography

    Immersion lithography is a technique used in semiconductor manufacturing to enhance the resolution and accuracy of the lithographic process. It involves using a liquid medium, typically water, between the lens and the wafer during exposure.

  5. Condenser (optics) - Wikipedia

    en.wikipedia.org/wiki/Condenser_(optics)

    As with objective lenses, a condenser lens with a maximum numerical aperture of greater than 0.95 is designed to be used under oil immersion (or, more rarely, under water immersion), with a layer of immersion oil placed in contact with both the slide/coverslip and the lens of the condenser. An oil immersion condenser may typically have NA of up ...

  6. Objective (optics) - Wikipedia

    en.wikipedia.org/wiki/Objective_(optics)

    Some microscopes use an oil-immersion or water-immersion lens, which can have magnification greater than 100, and numerical aperture greater than 1. These objectives are specially designed for use with refractive index matching oil or water, which must fill the gap between the front element and the object. These lenses give greater resolution ...

  7. Dark-field microscopy - Wikipedia

    en.wikipedia.org/wiki/Dark-field_microscopy

    To maximize the scattered light-gathering power of the objective lens, oil immersion is used and the numerical aperture (NA) of the objective lens must be less than 1.0. Objective lenses with a higher NA can be used but only if they have an adjustable diaphragm, which reduces the NA.

  8. Index-matching material - Wikipedia

    en.wikipedia.org/wiki/Index-matching_material

    In light microscopy, oil immersion is a technique used to increase the resolution of a microscope.This is achieved by immersing both the objective lens and the specimen in a transparent oil of high refractive index, thereby increasing the numerical aperture of the objective lens.

  9. Optical microscope - Wikipedia

    en.wikipedia.org/wiki/Optical_microscope

    These are used with index-matching material such as immersion oil or water and a matched cover slip between the objective lens and the sample. The refractive index of the index-matching material is higher than air allowing the objective lens to have a larger numerical aperture (greater than 1) so that the light is transmitted from the specimen ...