When.com Web Search

  1. Ad

    related to: calculate maximum available fault current

Search results

  1. Results From The WOW.Com Content Network
  2. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The effect of too high short-circuit current is discussed in the previous section. The short-circuit current should be around 20 times the rating of the circuit to ensure the branch circuit protection clears a fault quickly. Quick disconnecting is needed, because during a line-to-ground short circuit the grounding pin potential on the power ...

  3. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    Customers of an electrical supply utility can request the maximum value of prospective short-circuit current available at their point of supply. Networks involving multiple sources of current, such as multiple generators, electric motors, and with variable interconnections may be analyzed with a computer.

  4. IEEE 1584 - Wikipedia

    en.wikipedia.org/wiki/IEEE_1584

    Bolted fault current in the range of 700–106,000 A. Grounded or ungrounded. Equipment enclosures of commonly available sizes with various conductor configurations, or open air. Gaps between conductors. Faults involving three phases.

  5. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    In an electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker .

  6. Current limiting - Wikipedia

    en.wikipedia.org/wiki/Current_limiting

    When Q2 turns on, it removes the base current from Q1, thereby reducing the collector current of Q1, which is nearly the load current. Thus, R sens fixes the maximum current to a value given by 0.65/R sens. For example, if R sens = 0.33 Ω, the current is limited to about 2 A even if R load becomes a short (and V o becomes zero).

  7. Short circuit ratio (electrical grid) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    In an electrical grid, the short circuit ratio (or SCR) is the ratio of: the short circuit apparent power (SCMVA) in the case of a line-line-line-ground (3LG) fault at the location in the grid where some generator is connected, to: the power rating of the generator itself (GMW).

  8. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    Inrush current, input surge current, or switch-on surge is the maximal instantaneous input current drawn by an electrical device when first turned on. Alternating-current electric motors and transformers may draw several times their normal full-load current when first energized, for a few cycles of the input waveform.

  9. Power system simulation - Wikipedia

    en.wikipedia.org/wiki/Power_system_simulation

    Short circuit analysis analyzes the power flow after a fault occurs in a power network. The faults may be three-phase short circuit, one-phase grounded, two-phase short circuit, two-phase grounded, one-phase break, two-phase break or complex faults. Results of such an analysis may help determine the following: Magnitude of the fault current