Search results
Results From The WOW.Com Content Network
The thermodynamic method takes advantage of this fact, and precisely measures the temperature difference across a pump to calculate the pump's efficiency. Pressure measurements are used to calculate the head of the pump, and a power meter is used to measure input power to the pump. Using the measurements of temperature, power, and pressure ...
The purpose of the IPMVP is to increase certainty, reliability, and level of savings; reduce transaction costs by providing an international, industry consensus approach and methodologies; reduce financing costs by providing a project with a Measurement and Verification Plan (M&V Plan) standardisation, thereby allowing project bundling and pooled project financing.
Pump curves are quite useful in the pump selection, testing, operation and maintenance. Pump performance curve is a graph of differential head against the operating flow rate. They specify performance and efficiency characteristics. Performance tests are done on the pumps to verify the claims made by the pump maker.
The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [1] [2] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs. The COP is used in thermodynamics.
In fluid dynamics, total dynamic head (TDH) is the work to be done by a pump, per unit weight, per unit volume of fluid.TDH is the total amount of system pressure, measured in feet, where water can flow through a system before gravity takes over, and is essential for pump specification.
Example Number 1: A tank with a liquid level 2 metres above the pump intake, plus the atmospheric pressure of 10 metres, minus a 2 metre friction loss into the pump (say for pipe & valve loss), minus the NPSH R curve (say 2.5 metres) of the pre-designed pump (see the manufacturers curve) = an NPSH A (available) of 7.5 metres. (not forgetting ...
This comprises measurement of flow (FE) at the pump discharge, this measurement is an input to a flow controller (FIC) whose set point is the minimum flow required through the pump(see diagram). As the flow reduces to the minimum flow value the controller acts to open a flow control valve (FCV) to recycle fluid from the discharge back to the ...
Specific speed is an index used to predict desired pump or turbine performance. i.e. it predicts the general shape of a pump's impeller. It is this impeller's "shape" that predicts its flow and head characteristics so that the designer can then select a pump or turbine most appropriate for a particular application.