A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
Residual-current circuit breaker. Add languages. ... Download as PDF; Printable version; ... Redirect page. Redirect to: Residual-current device;
A mnemonic device for remembering the definitions of the directions of current and magnetic field in generators. ripple A periodic variation in the amplitude of a DC signal, such as found in a power supply with partly effective filtering. RLC circuit A circuit that has only resistors, inductors, and capacitors in it. robotics
Speed: Devices must function quickly to reduce equipment damage and fault duration, with only very precise intentional time delays. Sensitivity: Devices must detect even the smallest value of faults and respond. Economy: Devices must provide maximum protection at minimum cost. Simplicity: Devices must minimize protection circuitry and equipment.
A residual current device works by monitoring the active and neutral lines and tripping the active line if it notices a difference. [40] Residual current devices require a separate neutral line for each phase and to be able to trip within a time frame before harm occurs.
A residual-current device (RCD), or residual-current circuit breaker (RCCB), is a device that instantly breaks an electric circuit to prevent serious harm from an ongoing electric shock. A fuse or circuit breaker also does that, 'instantly' of course, is subject to qualification.
GTO thyristors suffer from long switch-off times, whereby after the forward current falls, there is a long tail time where residual current continues to flow until all remaining charge from the device is taken away. This restricts the maximum switching frequency to about 1 kHz. It may be noted, however, that the turn-off time of a GTO is ...
Electrical equipment may be designed with a floating ground for one of several reasons. One is safety. For example, a low-voltage DC power supply, such as a mobile phone charger, is connected to the mains through a transformer of one type or another, and there is no direct electrical connection between the current return path on the low-voltage side and physical ground (earth).