Search results
Results From The WOW.Com Content Network
In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to the other.
In electrical engineering, impedance is the opposition to alternating current presented by the combined effect of resistance and reactance in a circuit. [1]Quantitatively, the impedance of a two-terminal circuit element is the ratio of the complex representation of the sinusoidal voltage between its terminals, to the complex representation of the current flowing through it. [2]
Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power may be greater than the real power(pf ≤0.5). In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the ...
In power engineering, the power-flow study, or load-flow study, is a numerical analysis of the flow of electric power in an interconnected system. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system, and focuses on various aspects of AC power parameters, such as Voltage, voltage angles, real power and reactive power.
Torrent Power has an aggregate generating capacity of more than 4 GW with a unique mix of coal based, gas based, and renewable power plants comprising: . 1530 MW (4 Single Shaft Units of 382.5 MW each) SUGEN gas based mega combined cycle power plant in Akhakhol village near Surat - largest private sector gas based power plant in India.
A surge of energy on a finite transmission line will see an impedance of prior to any reflections returning; hence surge impedance is an alternative name for characteristic impedance. Although an infinite line is assumed, since all quantities are per unit length, the “per length” parts of all the units cancel, and the characteristic ...
The conductance of the dielectric material separating the two conductors is represented by a shunt resistor between the signal wire and the return wire (siemens per unit length). This resistor in the model has a resistance of R shunt = 1 G o h m s {\displaystyle R_{\text{shunt}}={\frac {1}{G}}\,\mathrm {ohms} } .
Blackman's theorem is a general procedure for calculating the change in an impedance due to feedback in a circuit. It was published by Ralph Beebe Blackman in 1943, [1] was connected to signal-flow analysis by John Choma, and was made popular in the extra element theorem by R. D. Middlebrook and the asymptotic gain model of Solomon Rosenstark.