When.com Web Search

  1. Ad

    related to: how to size parallel conductors

Search results

  1. Results From The WOW.Com Content Network
  2. Twin-lead - Wikipedia

    en.wikipedia.org/wiki/Twin-lead

    The name twin lead is most often used to refer specifically to 300 Ω (Ohm) ribbon cable, the most common type, but on occasion, twin lead is used to refer to any type of parallel wire line. Parallel wire line is available with several different values of characteristic impedance such as twin lead ribbon cable (300 Ω ), window line (300 Ω ...

  3. Transposition (transmission lines) - Wikipedia

    en.wikipedia.org/wiki/Transposition...

    For example, in star quad twisting the two conductors of a quadruple run parallel over the entire cable length. Capacitance between the conductors is thus substantially higher than with Dieselhorst Martin (DHM) stranding [ 5 ] in which the situation of the conductors to each other in the cable changes repeatedly.

  4. Overhead power line - Wikipedia

    en.wikipedia.org/wiki/Overhead_power_line

    Bundle conductors consist of several parallel cables connected at intervals by spacers, often in a cylindrical configuration. The optimum number of conductors depends on the current rating, but typically higher-voltage lines also have higher current. American Electric Power [17] is building 765 kV lines using six conductors per phase in a ...

  5. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    Because multiple conductors bundled in a cable cannot dissipate heat as easily as single insulated conductors, those circuits are always rated at a lower ampacity. Tables in electrical safety codes give the maximum allowable current based on size of conductor, voltage potential, insulation type and thickness, and the temperature rating of the ...

  6. Electrical length - Wikipedia

    en.wikipedia.org/wiki/Electrical_length

    The phase velocity at which electrical signals travel along a transmission line or other cable depends on the construction of the line. Therefore, the wavelength corresponding to a given frequency varies in different types of lines, thus at a given frequency different conductors of the same physical length can have different electrical lengths.

  7. Ribbon cable - Wikipedia

    en.wikipedia.org/wiki/Ribbon_cable

    Ribbon cables are usually specified by two numbers: the spacing or pitch of the conductors, and the number of conductors or ways. A spacing of 0.05 inch (1.27 mm) is the most usual, allowing for a two-row connector with a pin spacing of 0.1 inch (2.54 mm).

  8. Electric power transmission - Wikipedia

    en.wikipedia.org/wiki/Electric_power_transmission

    For large conductors (more than a few centimetres in diameter), much of the current flow is concentrated near the surface due to the skin effect. The center of the conductor carries little current but contributes weight and cost. Thus, multiple parallel cables (called bundle conductors) are used for higher capacity.

  9. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    Wiring systems in buildings may be subject to frequent alterations. Frequent wiring changes are made simpler and safer through the use of electrical conduit, as existing conductors can be withdrawn and new conductors installed, with little disruption along the path of the conduit. A conduit system can be made waterproof or submersible.