BS 546, "Two-pole and earthing-pin plugs, socket-outlets and socket-outlet adaptors for AC (50-60 Hz) circuits up to 250 V" describes four sizes of plug rated at 2 A, 5 A (Type D), 15 A (Type M) and 30 A. The plugs have three round pins arranged in a triangle, with the larger top pin being the earthing pin.
NEMA 5-15P plug and NEMA 5-15R receptacle (different scales, blade spacing is 0.5 inches (12.7 mm) for both.) Each receptacle also accepts an ungrounded plug, whether polarized or unpolarized. Typical 5-15R residential receptacle 5-20R T-slot receptacle mounted with the hole for the ground pin at the top. The neutral connection is the wider T ...
The National Electrical Code, 2008 edition. The National Electrical Code (NEC), or NFPA 70, is a regionally adoptable standard for the safe installation of electrical wiring and equipment in the United States. It is part of the National Fire Code series published by the National Fire Protection Association (NFPA), a private trade association. [1]
IEC 60309 (formerly IEC 309 and CEE 17, also published by CENELEC as EN 60309) is a series of international standards from the International Electrotechnical Commission (IEC) for "plugs, socket-outlets and couplers for industrial purposes".
BS 546, Two-pole and earthing-pin plugs, socket-outlets and socket-outlet adaptors for AC (50–60 Hz) circuits up to 250 V is an older British Standard for three-pin AC power plugs and sockets. Originally published in April 1934, it was updated by a 1950 edition which is still current, [1] with eight amendments up to 1999. BS 546 is also the ...
Electrical wiring practices developed in parallel in many countries in the late 19th and early 20th centuries. [7] As a result, national and regional variations developed and remain in effect. (see National Electrical Code, electrical wiring, electrical wiring in the United Kingdom). Some of these are retained for technical reasons, since the ...
The 16 amp version uses wider pin spacing and larger pins. Hybrid outlets that accept both types are common and some also accept type F. NB: 16 amp type C plugs, such as CEE 7/17 commonly found on hairdryers, will not fit type L outlets and need an adapter, or should be used with a type F or hybrid type L/F outlet. Jamaica: A, B 110 V
This has to do with a peculiarity of the National Electrical Code from 1923 to the 1950s. Originally, sockets were rated at 10 A 250 V, because the NEC limited lighting circuits to 10 A. In 1923, the code changed to allow lighting circuits to be fused at 15 A, but the previous 10 A rule still applied to circuits over 125 V. [ 22 ] The higher ...