When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Modbus - Wikipedia

    en.wikipedia.org/wiki/Modbus

    Modbus TCP nomenclature is the same as for the Modbus over Serial line protocol, as any device which send out a Modbus command, is the 'client' and the response comes from a 'server'. [29] The ADU for Modbus TCP is officially called Modbus TCP/IP ADU by the Modbus organization [30] and is also called Modbus TCP frame by other parties. [3]

  3. OpenSafety - Wikipedia

    en.wikipedia.org/wiki/OpenSAFETY

    It is based on its immediate precursor technology, POWERLINK Safety, which was originally launched in 2007. openSAFETY won broad public attention in April 2010, when a presentation at the Hannover Messe trade show in Germany showcased four different implementations of the safety solution running in SERCOS III, Modbus TCP, EtherNet/IP and ...

  4. Industrial Ethernet - Wikipedia

    en.wikipedia.org/wiki/Industrial_Ethernet

    Protocols for industrial Ethernet include EtherCAT, EtherNet/IP, PROFINET, POWERLINK, SERCOS III, CC-Link IE, and Modbus TCP. [1] [2] Many industrial Ethernet protocols use a modified media access control (MAC) layer to provide low latency and determinism. [1] Some microprocessors provide industrial Ethernet support.

  5. Fieldbus - Wikipedia

    en.wikipedia.org/wiki/Fieldbus

    Here we find the solutions Ethernet/IP, three versions of PROFINET IO - the classes A, B, and C - and the solutions of P-NET, [28] Vnet/IP [29] TCnet, [30] EtherCAT, Ethernet POWERLINK, Ethernet for Plant Automation (EPA), and also the MODBUS with a new Real-Time Publish-Subscribe MODBUS-RTPS and the legacy profile MODBUS-TCP.

  6. Talk:Modbus - Wikipedia

    en.wikipedia.org/wiki/Talk:Modbus

    "TCP MODBUS ADU = 253 bytes + MBAP (7 bytes) = 260 bytes." A total of 253 bytes for a Modbus PDU means that up to 125 registers can be read (there are no extra CRC bytes required for TCP connections). With function code 0x03 (Read Holding Registers) or 0x04 (Read Input Registers), the RESPONSE message size calculation is as follows:

  7. DNP3 - Wikipedia

    en.wikipedia.org/wiki/DNP3

    The focus of this extensive library was to eliminate the need for bit-mapping data over other objects, as is often done in many Modbus installations. For example, floating point number variants are available, so there is no need to map the number on to a pair of 16 bit registers. This improves compatibility and eliminates problems such as ...

  8. Troubleshoot a dial-up connection - AOL Help

    help.aol.com/articles/troubleshooting-a-dial-up...

    An active internet connection is required to be able to access all the best that America Online® offers. If you're using dial-up internet and can't connect, try the following troubleshooting steps: Check the dial tone - If you DO have one, it's likely the problem has something to do with your computer. If you DON'T, it's likely the problem has ...

  9. IEC 60870-6 - Wikipedia

    en.wikipedia.org/wiki/IEC_60870-6

    TCP/IP over Ethernet (802.3) seems to be the most common. ICCP may operate over a single point-to-point link between two control centres; however, the more general case is for many control centres and a routed wide area network. The logical connections or “associations” between control centres are completely general.