Note that, in approximation, for a given value of flow volume, a step up in duct size (say from 100mm to 120mm) will reduce the friction loss by a factor of 3. Volumetric Flow Q of air at STP where friction loss per unit length Δ p / L (SI kg / m 2 / s 2 ) is, resp., 0.082, 0.245, and 0.816., for selected Nominal Duct Sizes [ 19 ] in smooth ...
Q is the volumetric flow rate, used here to measure flow instead of mean velocity according to Q = π / 4 D c 2 <v> (m 3 /s). Note that this laminar form of Darcy–Weisbach is equivalent to the Hagen–Poiseuille equation , which is analytically derived from the Navier–Stokes equations .
For example, halving a pipe's diameter would increase the pressure drop by a factor of = (e.g. from 2 psi to 64 psi), assuming no change in flow. Pressure drop in piping is directly proportional to the length of the piping—for example, a pipe with twice the length will have twice the pressure drop, given the same flow rate. [ 8 ]
For the limiting case of a very wide duct, i.e. a slot of width b, where b ≫ a, and a is the water depth, then D H = 4a. For a fully filled duct or pipe whose cross-section is a convex regular polygon , the hydraulic diameter is equivalent to the diameter D {\displaystyle D} of a circle inscribed within the wetted perimeter .
The Hazen–Williams equation is an empirical relationship that relates the flow of water in a pipe with the physical properties of the pipe and the pressure drop caused by friction. It is used in the design of water pipe systems [ 1 ] such as fire sprinkler systems , [ 2 ] water supply networks , and irrigation systems.
Because they are used for domestic water measurement, piston meters, also known as rotary piston or semi-positive displacement meters, are the most common flow measurement devices in the UK and are used for almost all meter sizes up to and including 40 mm (1 + 1 ⁄ 2 in). The piston meter operates on the principle of a piston rotating within a ...
A process to perform a water flow test is explained in the model fire codes as published by NFPA (National Fire Protection Association). If a water supply source is considered weak compared to what is required by the sprinkler system design hydraulic calculation, the water pressure can be boosted by means of a fire pump.
The thermodynamic method takes advantage of this fact, and precisely measures the temperature difference across a pump to calculate the pump's efficiency. Pressure measurements are used to calculate the head of the pump, and a power meter is used to measure input power to the pump. Using the measurements of temperature, power, and pressure ...