Discharge pressure (also called high side pressure or head pressure) is the pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. The discharge pressure is affected by several factors: size and speed of the condenser fan, condition and cleanliness of the condenser coil, and the size of the ...
R-407C is a mixture of hydrofluorocarbons used as a refrigerant. It is a zeotropic blend of difluoromethane (R-32), pentafluoroethane (R-125), and 1,1,1,2-tetrafluoroethane (R-134a). Difluoromethane serves to provide the heat capacity, pentafluoroethane decreases flammability, tetrafluoroethane reduces pressure. [ 1 ]
R-410A is a refrigerant used in air conditioning and heat pump applications. It is a zeotropic but near-azeotropic mixture of difluoromethane (CH 2 F 2, called R-32) and pentafluoroethane (CHF 2 CF 3, called R-125). R-410A is sold under the trademarked names AZ-20, EcoFluor R410, Forane 410A, Genetron R410A, Puron, and Suva 410A.
A thermal expansion valve or thermostatic expansion valve (often abbreviated as TEV, TXV, or TX valve) is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator ...
Refrigeration has many applications, including household refrigerators, industrial freezers, cryogenics, and air conditioning. [5] [6] [7] Heat pumps may use the heat output of the refrigeration process, and also may be designed to be reversible, but are otherwise similar to air conditioning units. [5]
A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.
Some systems deal with flash-gas by separating it from the refrigerant that goes to the evaporator, as that portion of the refrigerant already evaporated and will only increase superheating. [6] One key feature when preventing flash-gas is the diameter of the piping. If the pipes are too thin and long, loss of pressure and friction tend to occur.
In refrigeration systems, subcooling the refrigerant is necessary to ensure the completion of the remaining stages of the refrigeration cycle. The subcooling stage provides certainty that the refrigerant is fully liquid before it reaches the next step on the cycle, the thermal expansion valve, where the presence of gas can be disruptive. [1]