  1. Results From The WOW.Com Content Network
  2. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.

  3. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    Dampers can also help adjust a HVAC system for seasonal use. [7] During winter months, for example, an air conditioning register can be closed to prevent cold air from being pulled from the room. This allows the hot air to mix more completely with the cold air in the room, improving the efficiency of the HVAC system. [7]

  4. Diffuser (thermodynamics) - Wikipedia

    en.wikipedia.org/wiki/Diffuser_(thermodynamics)

    A round diffuser in an HVAC system. Diffusers are very common in heating, ventilating, and air-conditioning systems. [3] Diffusers are used in both all-air and air-water HVAC systems, as part of room air distribution subsystems, and serve several purposes: To deliver both conditioning and ventilating air

  5. Displacement ventilation - Wikipedia

    en.wikipedia.org/wiki/Displacement_ventilation

    Displacement ventilation is best suited for taller spaces (higher than 3 meters [10 feet]). [2] Standard mixing ventilation may be better suited for smaller spaces where air quality is not as great a concern, such as single-occupant offices, and where the room height is not tall (e.g., lower than 2.3 meters [7.5 feet]).

  6. Air-mixing plenum - Wikipedia

    en.wikipedia.org/wiki/Air-mixing_plenum

    Air streams are mixed to save energy and improve energy efficiency by partially recirculating conditioned air.. The most common application for an air-mixing plenum is the mixing of return air (or extract air) with fresh air to provide a supply air mixture for onward distribution to the building or area which the ventilation system is serving. [1]

  7. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    When economizing, the control system will open (fully or partially) the outside air damper and close (fully or partially) the return air damper. This will cause fresh, outside air to be supplied to the system. When the outside air is cooler than the demanded cool air, this will allow the demand to be met without using the mechanical supply of ...