When.com Web Search

  1. Ads

    related to: 120v is how many watts in a house fan heat capacity formula

Search results

  1. Results From The WOW.Com Content Network
  2. Specific fan power - Wikipedia

    en.wikipedia.org/wiki/Specific_fan_power

    In reality the fan system efficiency is often in the range 0 to 60% (i.e. <); it is lowest for small fans or inefficient operating points (e.g. throttled flow or free-flow). The efficiency is a function of the total losses in the fan system, including aerodynamic losses in the fan, friction losses in the drive (e.g. belt), losses in the ...

  3. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The CLF is the cooling load at a given time compared to the heat gain from earlier in the day. [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load.

  4. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    A fan coil unit (FCU), also known as a Vertical Fan Coil Unit (VFCU), is a device consisting of a heat exchanger (coil) and a fan. FCUs are commonly used in HVAC systems of residential, commercial, and industrial buildings that use ducted split air conditioning or central plant cooling.

  5. Cooling capacity - Wikipedia

    en.wikipedia.org/wiki/Cooling_capacity

    Cooling capacity is the measure of a cooling system's ability to remove heat. [1] It is equivalent to the heat supplied to the evaporator/boiler part of the refrigeration cycle and may be called the "rate of refrigeration" or "refrigeration capacity".

  6. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  7. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    is the isobaric heat capacity of the fluid is 0.4 for heating (wall hotter than the bulk fluid) and 0.33 for cooling (wall cooler than the bulk fluid). [11] The fluid properties necessary for the application of this equation are evaluated at the bulk temperature thus avoiding iteration.

  8. Volt-ampere - Wikipedia

    en.wikipedia.org/wiki/Volt-ampere

    In direct current (DC) circuits, this product is equal to the real power, measured in watts. [3] The volt-ampere is dimensionally equivalent to the watt : in SI units , 1 V⋅A = 1 W. VA rating is most used for generators and transformers, and other power handling equipment, where loads may be reactive (inductive or capacitive).

  9. Heat capacity - Wikipedia

    en.wikipedia.org/wiki/Heat_capacity

    The heat capacity may be well-defined even for heterogeneous objects, with separate parts made of different materials; such as an electric motor, a crucible with some metal, or a whole building. In many cases, the (isobaric) heat capacity of such objects can be computed by simply adding together the (isobaric) heat capacities of the individual ...