Ad
related to: how to calculate moisture loss in construction materials worksheet templatehouzz.com has been visited by 10K+ users in the past month
Search results
Results From The WOW.Com Content Network
In 1907, Edgar Buckingham created the first water retention curve. [2] It was measured and made for six soils varying in texture from sand to clay. The data came from experiments made on soil columns 48 inch tall, where a constant water level maintained about 2 inches above the bottom through periodic addition of water from a side tube.
The building materials industry also manages the moisture barrier properties in architectural components to ensure the correct moisture levels in the internal spaces of buildings. Optoelectronic devices based on organic material, generally named OLEDs , need an encapsulation with low values of WVTR to guarantee the same performances over the ...
Moisture dew point is the temperature at which moisture condenses out of a gas. This parameter is inherently related to the moisture content, which defines the amount of water molecules as a fraction of the total. Both can be used as a measure of the amount of moisture in a gas and one can be calculated from the other fairly accurately.
A sieve analysis (or gradation test) is a practice or procedure used in geology, civil engineering, [1] and chemical engineering [2] to assess the particle size distribution (also called gradation) of a granular material by allowing the material to pass through a series of sieves of progressively smaller mesh size and weighing the amount of material that is stopped by each sieve as a fraction ...
The moisture content at which it takes 25 drops of the cup to cause the groove to close over a distance of 12.7 millimetres (0.50 in) is defined as the liquid limit. The test is normally run at several moisture contents, and the moisture content which requires 25 blows to close the groove is interpolated from the test results.
The maximum dry density is finally obtained from the peak point of the compaction curve and its corresponding moisture content, also known as the optimal moisture content. The testing described is generally consistent with the American Society for Testing and Materials (ASTM) standards, and are similar to the American Association of State ...
When wood is used as a construction material, whether as a structural support in a building or in woodworking objects, it will absorb or expel moisture until it is in equilibrium with its surroundings. Equilibration (usually drying) causes unequal shrinkage in the wood, and can cause damage to the wood if equilibration occurs too rapidly.
Equilibrium moisture content of wood versus humidity and temperature, according to the Hailwood-Horrobin equation. The equilibrium moisture content (EMC) of a hygroscopic material surrounded at least partially by air is the moisture content at which the material is neither gaining nor losing moisture.