Rooftop This is a very common unit type. The rising cost of energy means that air conditioning manufacturers must develop a new generation of high-efficiency, cost-effective air conditioners for commercial buildings that meet or exceed a part-load efficiency standard of typically 18 IEER. The aim is to reduce energy use by 30% over current ...
Central, "all-air" air-conditioning systems (or package systems) with a combined outdoor condenser/evaporator unit are often installed in North American residences, offices, and public buildings, but are difficult to retrofit (install in a building that was not designed to receive it) because of the bulky air ducts required. [32] (Minisplit ...
The efficiency of air conditioners is often rated by the seasonal energy efficiency ratio (SEER), which is defined by the Air Conditioning, Heating and Refrigeration Institute in its 2008 standard AHRI 210/240, Performance Rating of Unitary Air-Conditioning and Air-Source Heat Pump Equipment. [61]
rooftop unit (RTU) A packaged unit that controls both heating and air conditioning. An air handler typically refers to a unit that provides a fan to support either heating or cooling. radiant ceiling panels Usually metal panels suspended under the ceiling, insulated from the building structure.
This is a vast improvement from traditional active cooling units which have an overhead of 30-70%. [6] However, this novel and complicated method requires careful and expensive planning from mechanical engineers, who must work closely with the engineers designing the electrical and plumbing systems for a building.
Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...
DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...
The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.