Operative temperature or PMV should be calculated at 0.6 m for seated occupants, 1.1 m for standing occupants, and the mean height of the body for horizontal occupants. [10] Local discomfort caused by floor temperature and radiant temperature asymmetry should be measured at the floor surface and at the occupants’ locations, respectively. [12]
A digital thermometer reading an ambient temperature of 36.4°C (97°F) in an unventilated room during a heat wave; a high indoor temperature can cause heat exhaustion or heat stroke in a person. The World Health Organization in 1987 found that comfortable indoor temperatures of 18–24 °C (64–75 °F) were not associated with health risks ...
The air temperature is the average temperature of the air surrounding the occupant, with respect to location and time. According to ASHRAE 55 standard, the spatial average takes into account the ankle, waist and head levels, which vary for seated or standing occupants.
Operative temperature is used in heat transfer and thermal comfort analysis in transportation and buildings. [10] Most psychrometric charts used in HVAC design only show the dry bulb temperature on the x-axis(abscissa), however, it is the operative temperature which is specified on the x-axis of the psychrometric chart illustrated in ANSI/ASHRAE Standard 55 – Thermal Environmental Conditions ...
The operative temperature, which is a more functional measure of thermal comfort in a building, is calculated from air temperature, mean radiant temperature and air speed. [6] Maintaining a balance between the operative temperature and the mean radiant temperature can create a more comfortable space. [ 7 ]
A medical/clinical thermometer showing the temperature of 38.7 °C (101.7 °F) Temperature measurement (also known as thermometry) describes the process of measuring a current temperature for immediate or later evaluation. Datasets consisting of repeated standardized measurements can be used to assess temperature trends.
Other fixed points used in the past are the body temperature (of a healthy adult male) which was originally used by Fahrenheit as his upper fixed point (96 °F (35.6 °C) to be a number divisible by 12) and the lowest temperature given by a mixture of salt and ice, which was originally the definition of 0 °F (−17.8 °C). [37]
Converting units of temperature differences (also referred to as temperature deltas) is not the same as converting absolute temperature values, and different formulae must be used. To convert a delta temperature from degrees Fahrenheit to degrees Celsius, the formula is {ΔT} °F = 9 / 5 {ΔT} °C.