  1. Results From The WOW.Com Content Network
  2. Hot water reset - Wikipedia

    en.wikipedia.org/wiki/Hot_water_reset

    Hot water reset, also called outdoor reset (ODR), is an energy-saving automatic control algorithm for heating boilers that are typically fired with fuel oil or natural gas.A hot water reset control loop measures the outside air temperature; this information is used to estimate demand or heating load as the outdoor temperature varies.

  3. Boiler - Wikipedia

    en.wikipedia.org/wiki/Boiler

    Boilers generally have 2 or 3 pressuretrols: a manual-reset pressuretrol, which functions as a safety by setting the upper limit of steam pressure, the operating pressuretrol, which controls when the boiler fires to maintain pressure, and for boilers equipped with a modulating burner, a modulating pressuretrol which controls the amount of fire.

  4. Control loop - Wikipedia

    en.wikipedia.org/wiki/Control_loop

    A control loop is the fundamental building block of control systems in general and industrial control systems in particular. It consists of the process sensor, the controller function, and the final control element (FCE) which controls the process necessary to automatically adjust the value of a measured process variable (PV) to equal the value of a desired set-point (SP).

  5. Integral windup - Wikipedia

    en.wikipedia.org/wiki/Integral_windup

    Within modern distributed control systems and programmable logic controllers, it is much easier to prevent integral windup by either limiting the controller output, limiting the integral to produce feasible output, [5] or by using external reset feedback, which is a means of feeding back the selected output to the integral circuit of all ...

  6. Open-loop controller - Wikipedia

    en.wikipedia.org/wiki/Open-loop_controller

    The control action is the switching on/off of the boiler, but the controlled variable should be the building temperature, but is not because this is open-loop control of the boiler, which does not give closed-loop control of the temperature. In closed loop control, the control action from the controller is dependent on the process output.

  7. Proportional–integral–derivative controller - Wikipedia

    en.wikipedia.org/wiki/Proportional–integral...

    Tuning a control loop is the adjustment of its control parameters (proportional band/gain, integral gain/reset, derivative gain/rate) to the optimum values for the desired control response. Stability (no unbounded oscillation) is a basic requirement, but beyond that, different systems have different behavior, different applications have ...