Search results
Results From The WOW.Com Content Network
A potentiometric surface is the imaginary plane where a given reservoir of fluid will "equalize out to" if allowed to flow. A potentiometric surface is based on hydraulic principles. For example, two connected storage tanks with one full and one empty will gradually fill/drain to the same level. This is because of atmospheric pressure and gravity.
Typically this equation is used to find the average T and S values near a pumping well, from drawdown data collected during an aquifer test. This is a simple form of inverse modeling, since the result ( s ) is measured in the well, r , t , and Q are observed, and values of T and S which best reproduce the measured data are put into the equation ...
The circles are divided by equally spaced radial lines. The radii of the circles are equal to the R/z values corresponding to F U K〖∆σ〗_z/q = 0, 0.1, 0.2,...,1. There are nine circles shown since when 〖∆σ〗_z/q = 0, R/z = 0 also. The unit length for plotting the circles is AB. [1]
For general purposes, buffers at pH 4.00 and pH 10.00 are suitable. The pH meter has one calibration control to set the meter reading equal to the value of the first standard buffer and a second control to adjust the meter reading to the value of the second buffer. A third control allows the temperature to be set.
Potentiometric solid state gas sensors have been generally classified into three broad groups. Type I sensors have an electrolyte containing mobile ions of the chemical species in the gas phase that it is monitoring. The commercial product, YSZ oxygen sensor, [1] is an example of type I.
In engineering, the Moody chart or Moody diagram (also Stanton diagram) is a graph in non-dimensional form that relates the Darcy–Weisbach friction factor f D, Reynolds number Re, and surface roughness for fully developed flow in a circular pipe. It can be used to predict pressure drop or flow rate down such a pipe.
Therefore, the difference in potential between the two electrodes gives an assessment of the sample's composition. In fact, since the potentiometric measurement is a non-destructive measurement, assuming that the electrode is in equilibrium with the solution, we are measuring the solution's potential.
Total ionic strength adjustment buffer (TISAB) is a buffer solution which increases the ionic strength of a solution to a relatively high level. This is important for potentiometric measurements, including ion selective electrodes, because they measure the activity of the analyte rather than its concentration.